Specifications
30 Pound Capacity Models (North American Approval)
Voltage Designation Specifications
Code Voltage Cycle Phase Wire
Full
Load
Amps
Circuit
Break-
er AWG mm2
Q Standard 200–208 50/60 3 3 4 15 14 2.5
Electric
Heat
220-240 22 30 10 6.0
N 440–480 50/60 3 3 3 15 14 2.5
P Standard 380–415 50/60 3 3 3 15 14 2.5
Electric
Heat
13 15 14 2.5
NOTE: Wire sizes shown are for copper, THHN, 90°C conductor per NEC article 310.
Table 26
40 Pound Capacity Models (North American Approval)
Voltage Designation Specifications
Code Voltage Cycle Phase Wire
Full
Load
Amps
Circuit
Break-
er AWG mm2
F and V-Speed Models (unless otherwise noted)
B 120 60 1 2 16 20 12 4
X (F-speed) 200–208 50/60 1/3 2/3 6/4 15 14 2.5
220-240
X (V-speed) 200–208 50/60 1/3 2/3 7/4 15 14 2.5
220-240
Q Standard 200-208 50/60 3 3 4 15 14 2.5
Electric
Heat
220-240 42 50 8 10.0
N Standard 440-480 50/60 3 3 3 15 14 2.5
Electric
Heat
22 30 10 6.0
Table 27 continues...
Installation
©
Copyright, Alliance Laundry Systems LLC -
DO NOT COPY or TRANSMIT
53 Part No. F8429301ENR15