Specifications

Floor Load Data
Specification 20 30 40 60 80 100
Dynamic floor load, lbs. [kN] 420 [1.86] 630 [2.80] 840 [3.74] 1260 [5.61] 1680 [7.48] 1680 [7.48]
Dynamic floor pressure, lbs.-
ft2 [kN-m
2
]
96 [4.60] 109 [5.22] 119 [5.70] 143 [6.85] 149 [7.13] 149 [7.13]
Dynamic load
frequency, Hz
F-speed 9.7 9.0 8.6 8.1 7.4 7.4
V-speed 13.7 12.8 12.2 11.4 10.4 9.5
Maximum moment about ma-
chine base, lbs.-ft. [kN-m]
805 [1.09] 1260 [1.71] 1820 [2.47] 2770 [3.76] 4330 [5.87] 4330 [5.87]
Maximum vertical load, lbs.
[kN]
795 [3.54] 1150 [5.12] 1470 [6.54] 2080 [9.25] 3050 [13.57] 3140 [13.82]
N/A = Not Applicable
Table 19
Drain Connection
IMPORTANT: Machine must be installed in accordance
with all local codes and ordinances.
All drain systems must be vented to prevent an air lock or siphon-
ing.
Use the supplied black rubber adapter and clamps to transition
from the machine drain outlet to the 2 inches [51 mm] schedule
40 PVC plumbing (20 and 30 models) and the 3 inches [76
mm]schedule 40 PVC plumbing (40-100 models).
If proper drain size is not available or practical, a surge tank is
required. A surge tank along with a sump pump should be used
when gravity drainage is not possible.
Installation
©
Copyright, Alliance Laundry Systems LLC -
DO NOT COPY or TRANSMIT
44 Part No. F8429301ENR15