Specifications
Elevated Pad, in. [mm]
Description 20-30
40-60
(F-speed)
40-60
(V-speed)
80-100
A Height of elevated pad above floor
(maximum)
8 [203] 8 [203] 8 [203] 8 [203]
B Distance between reinforcing bars
(maximum)
12 [305] 12 [305] 12 [305] 12 [305]
C Length of reinforcing bar extending in-
to existing floor (minimum)
2.5 [64] 2.5 [64] 2.5 [64] 2.5 [64]
D Total depth of foundation (concrete
plus 6 in. [152 mm] fill) (minimum)
8 [203] 8 [203] 12 [305] 15 [381]
E Required thickness of existing floor
(minimum)
4 [102] 4 [102] 6 [152] 6 [152]
Table 16
Tie-in to Existing Floor (refer to Table 17
)
CHM2390N_SVG
1
2
B
C
D
A
4
5
3
1. Existing Floor
2. 3500 PSI (minimum) Concrete
3. Reinforcing Bar
4. Perimeter Reinforcing Bar
5. Compacted Fill (minimum 6 in. [152 mm])
Figure 18
Tie-in to Existing Floor, in. [mm]
Description 20-30
40-60
(F-speed)
40-60
(V-speed)
80-100
A Required thickness of existing floor
(minimum)
4 [102] 4 [102] 6 [152] 6 [152]
Table 17 continues...
Installation
©
Copyright, Alliance Laundry Systems LLC -
DO NOT COPY or TRANSMIT
40 Part No. F8429301ENR15