Specifications
© Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT
Specifications and Dimensions
C003292ENR1
30
Water Connection
Water service should have the following:
• Hot water temperature should be a maximum of
190°F (88°C).
• Water pressure should be between 30 and 85 psi
(2 to 7 bar).
• Install screen filters in water supply lines to keep
rust, grit or other foreign material out of solenoid
valves.
• Suitable air cushions (risers) should be installed
in supply lines to prevent “hammering.” Refer to
Figure 14.
To connect water feeders to rear of machine, use
flexible hoses. Because this is a vibrating machine,
water lines must allow for movement or leaks may
result. Hang hoses in a large loop behind machine so
that they are not kinked or pinched.
For machines labeled with the CE mark, backsiphon
protection devices must be installed previous of all
machine water inlet valves in accordance with
accepted European standards.
To prevent personal injury, avoid contact
with inlet water temperatures higher than
125° Fahrenheit (51° Celsius) and hot
surfaces.
W748
WARNING
P038I
1 Air Cushions (Risers)
2 Water Supply Faucets
Figure 14
P038I
1
2