Specifications

© Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT
Specifications and Dimensions
21
C003292ENR1
Installation Instructions
Surface
These machines must be securely anchored on a solid,
flat reinforced concrete surface capable of
withstanding the weight of the machine and the
considerable forces generated during the spin/extract
cycle. Surface should be a high quality concrete
(minimum 3500 psi test strength) and at least 12 in.
(305 mm) thickness for all models. The surface should
be clean, flat and free of irregularities. The pad should
be 12 in. (305 mm) larger than the footprint of the
machine on all sides, beveling out towards the bottom
of the pad.
Anchors
The use of a minimum Grade 5 SAE rated 3/4 inch (19
mm) anchor bolt is recommended for installing
machines.
Mounting
On Metal Base
NOTE: Installation on a raised metal base is not
recommended.
On Concrete
Refer to Grouting and Setting Machine section.
Mounting Bolt Installation
Requirements
Location
Plan the location of the machines. When placing
machines consider the following:
The loading door is easily accessible to your
workers and does not interfere with other
equipment.
Make sure that the machine does not block
emergency exits, open doors, work traffic paths,
etc.
There is adequate clearance in front of the
machine for operation.
There is clearance behind and above the machine
to safely perform periodic maintenance. Always
check local codes. Refer to Clearances section.
Always mount this machine on a solid,
stable ground floor.
Never install a hard mount washer-
extractor on an above ground floor or
over a basement.
Never use any material between the
machine and floor except grout. The use
of rubber pads, neoprene or other
materials will make the installation
unsafe, noisy and will void all
warranties.
W706
WARNING
To reduce the risk of fire, serious injury,
property damage and/or death, install the
machine on a level (within 3/8 inch),
uncovered concrete floor of sufficient
strength at grade.
W787
WARNING