Instruction manual
Programming Control
802953
40
© Published by permission of the copyright owner – DO NOT COPY or TRANSMIT
Fill/Agitate
Step
Description Status/Value
Factory Default
Setting – Stage 4
Factory Default
Setting – Stage 6
Factory Default
Setting – Stage 8
“AdUr” Agitate
Duration
(in minutes)
1-25 NORMAL 90, NORMAL
60 = 9
NORMAL 40 = 7
PERM PRESS 60 = 6
DELICATES 30,
DELICATES COLD = 5
22
“ASPd” Agitate Speed “rEg” = regular
speed
“Lo” = low speed
NORMAL 90, NORMAL
60, NORMAL 40, PERM
PRESS 60 = “rEg”
DELICATES 30,
DELICATES COLD =
“Lo”
NORMAL 90, NORMAL
60, NORMAL 40, PERM
PRESS 60 = “rEg”
DELICATES 30 = “rEg”
(software version “S 01”)
“Lo” (software version
“S 02” or higher)
DELICATES COLD =
“Lo”
NORMAL 90,
NORMAL 60,
NORMAL 40, PERM
PRESS 60 = “rEg”
DELICATES 30,
DELICATES COLD =
“Lo”
“tEnP” Fill Water
Temperature
“Hot” = hot fill
“bIFL” = hot and
cold fill
“CoLd” = cold
fill
NORMAL 90, NORMAL
60, PERM PRESS 60 =
“Hot”
NORMAL 40 = “bIFL”
DELICATES 30,
DELICATES COLD =
“CoLd”
“CoLd”“CoLd”
“CLdn” Clothes Cool
Down
“on”/“oFF” NORMAL 90, NORMAL
60, PERM PRESS 60 =
“on”
NORMAL 40,
DELICATES 30,
DELICATES COLD =
“oFF”
“oFF”“oFF”
“HEAt” Heater
Setpoint
0 - 90 (degrees
Celsius)
NORMAL 90 = 90
NORMAL 60, PERM
PRESS 60 = 60
NORMAL 40 = 40
DELICATES 30 = 30
DELICATES COLD = 0
00
“dISP” Dispensers Press START
(enter) to access
options
“dEt” Detergent/
Bleach
“on”/“oFF”“on”“on”“on”
“SoFt” Softener “on”/“oFF”“oFF”“oFF”“on”
“oPt” Optional
Dispenser
“on”/“oFF”“on”“oFF”“oFF”
Table 7
NOTE: This programming option is only for machines factory- equipped with supply injection set-up.