Instruction manual

Programming Control
802953
40
© Published by permission of the copyright owner – DO NOT COPY or TRANSMIT
Fill/Agitate
Step
Description Status/Value
Factory Default
Setting – Stage 4
Factory Default
Setting – Stage 6
Factory Default
Setting – Stage 8
AdUr Agitate
Duration
(in minutes)
1-25 NORMAL 90, NORMAL
60 = 9
NORMAL 40 = 7
PERM PRESS 60 = 6
DELICATES 30,
DELICATES COLD = 5
22
ASPd Agitate Speed rEg” = regular
speed
Lo” = low speed
NORMAL 90, NORMAL
60, NORMAL 40, PERM
PRESS 60 = “rEg
DELICATES 30,
DELICATES COLD =
Lo
NORMAL 90, NORMAL
60, NORMAL 40, PERM
PRESS 60 = “rEg
DELICATES 30 = “rEg
(software version “S 01”)
Lo” (software version
“S 02” or higher)
DELICATES COLD =
Lo
NORMAL 90,
NORMAL 60,
NORMAL 40, PERM
PRESS 60 = “rEg
DELICATES 30,
DELICATES COLD =
Lo
tEnP Fill Water
Temperature
Hot” = hot fill
bIFL” = hot and
cold fill
CoLd” = cold
fill
NORMAL 90, NORMAL
60, PERM PRESS 60 =
Hot
NORMAL 40 = “bIFL
DELICATES 30,
DELICATES COLD =
CoLd
CoLd”“CoLd
CLdn Clothes Cool
Down
on”/“oFF NORMAL 90, NORMAL
60, PERM PRESS 60 =
on
NORMAL 40,
DELICATES 30,
DELICATES COLD =
oFF
oFF”“oFF
HEAt Heater
Setpoint
0 - 90 (degrees
Celsius)
NORMAL 90 = 90
NORMAL 60, PERM
PRESS 60 = 60
NORMAL 40 = 40
DELICATES 30 = 30
DELICATES COLD = 0
00
dISP Dispensers Press START
(enter) to access
options
dEt Detergent/
Bleach
on”/“oFF”“on”“on”“on
SoFt Softener on”/“oFF”“oFF”“oFF”“on
oPt Optional
Dispenser
on”/“oFF”“on”“oFF”“oFF
Table 7
NOTE: This programming option is only for machines factory- equipped with supply injection set-up.