Instruction manual

Programming Control
802953
18
© Published by permission of the copyright owner – DO NOT COPY or TRANSMIT
(continued)
Option
Number
Option
Display
Description Factory Default Value Range
a“CnP1 Cycle Modifier B Price 25 0 - 65,535
b“CnP2 Cycle Modifier C Price 50 0 - 65,535
c“CnP3 Cycle Modifier B Option 2 0 - 15
d“CnP4 Cycle Modifier C Option 3 0 - 15
e“CnP5 Cycle Modifier Added Wash Time 2 0 - 15
*f CnP6 Default Cycle Modifier 0 0 - 2
*24 PCt- Cycle Time Display
*a PCtE Cycle Time Display Enable oFF on/oFF
*b PCt1 Cycle #1 Time 34 0 - 255
*c PCt2 Cycle #2 Time 34 0 - 255
*d PCt3 Cycle #3 Time 32 0 - 255
*e PCt4 Cycle #4 Time 31 0 - 255
*f PCt5 Cycle #5 Time 28 0 - 255
*g PCt6 Cycle #6 Time 28 0 - 255
25 droP Drop Off Mode (On/Off) oFF on/oFF
26 LPSA Low Power/Auto Shutdown A Days Enable
(On/Off)
oFF on/oFF
27 LPSb Low Power/Auto Shutdown B Days Enable
(On/Off)
oFF on/oFF
28 LPSC Low Power/Auto Shutdown C Days Enable
(On/Off)
oFF on/oFF
29 LPSd Low Power/Auto Shutdown D Days Enable
(On/Off)
oFF on/oFF
30 PFr Power Fail Reset oFF oFF/133 - 255
31 IrA IR Access (On/Off) on on/oFF
32 rAEn Manual Rapid Advance (On/Off) on on/oFF
33 dAEn Manual Diagnostics (On/Off) on on/oFF
34 PtEn Production Test Cycle (On/Off) on on/oFF
*This option available in software version “S 02” or higher only.