Operating instructions

Enter to retry
Clear to stop
Figure 9
If Enter (START) key is pressed during fill alarm, condition will
end and step will start over. If programmed water level is not
reached within programmed step time, fill alarm will occur again
Refer to Figure 9 .
Done Cycle CC
Figure 10
If Clear (STOP) key is pressed while fill alarm is in effect, cycle
will end, and door will unlock. Refer to Figure 10 .
Please open door
Figure 11
If no action is taken, and fill level is not reached within two (2)
minute alarm time limit, cycle will end and door can be unlocked
(provided no water level is sensed). Refer to Figure 11 .
Whenever a fill alarm occurs during a cycle, display will repeat
the messages shown on the left at end of stop routine, before door
is opened, to indicate alarm condition occurred in cycle.
Possible Faults:
Wiring is disconnected.
Broken inlet valve.
Problem with water supply.
Inlet valves are blocked by dirt.
The water pressure hose is broken or not connected properly.
Drain Alarm
Waterlevel
10.2 cm
Figure 12
If drain step is NOT followed by a spin and if machine does not
empty within the time programmed for drain step, a drain alarm
occurs. Display will read “Didn’t drain within time.”
During drain alarm, beeper sounds on and off, and machine con-
tinues attempting to drain. If machine does not empty, condition
continues.
Enter to retry
Clear to stop
Figure 13
If Enter (START) key is pressed, drain alarm ends, and drain step
starts over at beginning. If machine has not emptied when drain
step time expires, alarm occurs again.
If Clear (STOP) key is pressed while drain alarm is in effect, dis-
play shows water level (inches or centimeters), but otherwise
takes no new action since machine has not emptied.
Done Cycle CC
Figure 14
Please open door
Figure 15
When cycle ends, display will briefly repeat the messages shown
on the left until door is opened (to indicate that an alarm condi-
tion occurred in the cycle).
During step N
Figure 16
If machine drains during a spin step prior to accelerating into
high speed and if machine has not emptied within approximately
two (2) minutes of starting drain procedure, a drain alarm occurs.
There is no rotation during this alarm; messages displayed are
identical to drain alarm during a drain step not followed by a
spin.
If Enter (START) key is pressed during drain alarm in a spin
step, the alarm will stop and the spin step will start over. Machine
will rotate at wash speed forward, then transition to distribution
speed.
After drain begins (i.e. drain open, pumping begins), if two (2)
additional minutes elapse, alarm occurs again.
Temperature Sensor Error
The temperature was never reached in this cycle, indicating a
problem with heating, and the control shows “Temperature sen-
sor error”.
Possible Faults:
Bad temperature probe.
Operation
D1385ENR6
©
Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT 11