Service manual
62 M411433
Section 5 Service Procedures
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the tumbler before servicing.
• Close gas shut-off valve to gas tumbler before servicing.
• Close steam valve to steam tumbler before servicing.
• Never start the tumbler with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the tumbler is properly grounded.
W002
WARNING
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
76. CYLINDER DRIVE MOTOR
(Reversing Tumblers)
a. Support drive guard and remove the screws
holding it to the back panel of the tumbler.
Leave the belt guard attached to the top of the
drive guard.
b. Loosen four capscrews holding motor
mounting bracket to side brackets. Lower
motor and mounting bracket until holding
capscrews bottom in the mounting slots.
On later models, lower adjusting bolt to lessen
belt tension.
c. Slip drive belt off of the motor pulley.
d. Disconnect the wire harness from motor.
e. Remove the four capscrews, nuts, lockwashers
and flat washers holding the motor to the
mounting bracket.
f. Loosen the setscrews in the motor pulley and
remove pulley by using a suitable puller.
NOTE: Refer to wiring diagram when rewiring the
motor.
g. After installing motor, adjust drive belt tension,
and adjust motor position on mounting bracket.
Figure 37
T472P_
ADJUSTING
BOLT
CYLINDER
MOTOR
MOTOR
PULLEY
MOTOR
BRACKET
After 1996: