Service manual

M411433 47
Section 5 Service Procedures
To reduce the risk of electric shock, fire, explosion, serious injury or death:
Disconnect electric power to the tumbler before servicing.
Close gas shut-off valve to gas tumbler before servicing.
Close steam valve to steam tumbler before servicing.
Never start the tumbler with any guards/panels removed.
Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the tumbler is properly grounded.
W002
WARNING
© Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT
55. LOADING DOOR ASSEMBLY
Refer to Figure 21.
a. Open loading door.
b. While supporting door, remove upper hinge
bolt holding door to hinge bracket.
c. Remove door from hinge bracket.
NOTE: Nylon washer must be in place on lower pin
when reinstalling loading door.
56. LOADING DOOR HINGE
a. Open loading door.
b. While supporting door, remove upper hinge
bolt holding door to hinge bracket. Refer to
Figure 21.
c. Remove door from hinge bracket.
d. Remove nuts and screws holding hinge to door
frame. Refer to Figure 22.
Figure 21
T028SE1A
HINGE
BRACKET
HINGE
BOLT
LOADING
DOOR
ASSEMBLY
Figure 22
T029SE1A
LOADING
DOOR
HINGE
HINGE
ATTACHING
SCREWS