Service manual
M411433 35
Section 5 Service Procedures
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the tumbler before servicing.
• Close gas shut-off valve to gas tumbler before servicing.
• Close steam valve to steam tumbler before servicing.
• Never start the tumbler with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the tumbler is properly grounded.
W002
WARNING
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
37. CONTROL THERMOSTAT
a. Remove control panel.
b. Pull off thermostat knob. Refer to Figure 10.
c. Disconnect wires from thermostat.
d. Remove two screws holding thermostat to
bracket.
e. Remove wire-way attaching screws. Refer to
Figure 11.
f. Remove screws, wire clips and/or retaining
straps securing thermostat sensing tube in wire-
way.
g. Remove junction box cover attaching screws.
Refer to Figure 11.
IMPORTANT: When reinstalling thermostat, be
sure to install all screws and wire clips and replace
all retaining straps removed in step “f” and “g”.
h. Unlock and remove lint panel.
i. Spread locking tabs on sensing probe bracket
and disengage probe from bracket. Refer to
Figure 12.
IMPORTANT: When reinstalling thermostat, be
sure to secure sensing probe with locking tabs on
bracket.
j. Carefully remove thermostat, tube and probe.
IMPORTANT: Do not kink sensing tube when
installing thermostat.
NOTE: Refer to wiring diagram when rewiring
thermostat.
Figure 10
SCREWS
T012SE1B
THERMOSTAT
KNOB
THERMOSTAT
BRACKET
SENSING
TUBE
Figure 11
TU013-SV
THERMOSTAT
SENSING TUBE
JUNCTION
BOX
WIRE
TIES
WIRE
WAY