22 M411433
Section 3 Troubleshooting
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the tumbler before servicing.
• Close gas shut-off valve to gas tumbler before servicing.
• Close steam valve to steam tumbler before servicing.
• Never start the tumbler with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be 
reconnected to ensure that the tumbler is properly grounded.
W002
WARNING
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
20. IGNITER DOES NOT GLOW
(White Rodgers Glow-Bar System)
21. IGNITER GLOWS CONSTANTLY
22. IGNITER GLOWS, CYCLES OFF BUT BURNER DOES NOT IGNITE
ARE 80 - 120 VOLTS 
PRESENT BETWEEN 
BLACK WIRE AND 
GROUND ON MAIN 
THERMOSTAT?
YES
NO
CHECK 
HEAT CIRCUIT
ARE 80 - 120 VOLTS 
PRESENT BETWEEN 
WIRES OF IGNITER 
BRACKET?
ARE 80 - 120 VOLTS 
PRESENT BETWEEN 
EACH OF THE PURPLE 
WIRES OF SENSOR AND 
GROUND?
NO
YES
REPLACE 
IGNITER
NO
REPLACE 
DIODE LOGIC BOARD
REPLACE 
SENSOR
ARE 80 - 120 VOLTS 
PRESENT ACROSS 
THE RED AND WHITE 
WIRES OF THE 
REDUNDANT COIL?
NO
CAN YOU 
HEAR THE 
REDUNDANT 
COIL 
OPEN?
NO
REPLACE
COMPLETE 
GAS VALVE
NO
ARE 40 - 60 VOLTS  
PRESENT ACROSS 
THE PURPLE WIRES 
TO THE 
MAIN COIL?
IS GAP BETWEEN 
IGNITER 
AND BURNER
1/8 IN. TO 1/4 IN.?
NO
ADJUST 
IGNITER GAP TO 
1/8 IN. TO 1/4 IN.
YES YES YES
REPLACE DIODE
LOGIC BOARD
REPLACE DIODE
LOGIC BOARD
CAN YOU 
HEAR THE 
MAIN COIL 
CLICK 
OPEN?
NO
REPLACE
MAIN COIL
YES