To reduce the risk of electric shock, fire, explosion, serious injury or death:
Disconnect electric power to the tumbler before servicing.
Close gas shut-off valve to gas tumbler before servicing.
Close steam valve to steam tumbler before servicing.
Never start the tumbler with any guards/panels removed.
Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the tumbler is properly grounded.
W002
WARNING
© Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT
8. HEATING ELEMENT OR BURNER SHUTS-OFF PREMATURELY
9. HEATING ELEMENT OR BURNER REPEATEDLY CYCLES OFF ON HIGH LIMIT
THERMOSTAT
POSSIBLE CAUSE TO CORRECT
Improper or inadequate exhaust and/or make-up air
system.
Refer to Installation Manual (supplied with tumbler) for
exhaust and make-up air requirements.
Gas Models: Insufficient gas supply Open partially closed gas shut-off valve, or correct low
pressure.
Gas Models: Tumbler not properly equipped for
type of gas used.
Tumbler is equipped for type of gas specified on serial
plate. If orifices are different from that specified on serial
plate, obtain and install proper orifices.
Gas Models: Improperly adjusted burner flame. Refer to Adjustment Section for burner flame adjustment.
Gas Models: (Glow-Bar Ignition) Sensor contact
closing.
Replace sensor.
Cycling off on limit thermostat. Refer to Paragraph 9.
Broken, loose or incorrect wiring. Refer to wiring diagram located on back of tumbler or in
literature packet.
POSSIBLE CAUSE TO CORRECT
External exhaust system is longer than
recommended or inadequate make-up air.
Refer to Installation Manual (supplied with tumbler) for
exhaust and make-up air requirements.
Clogged lint screen. Remove screen and clean. Lint screen and compartment
should be cleaned after every eight hour shift.
Lint in tumbler ducts. Clean tumbler ducts
Lint in external exhaust system. Disassemble exhaust system and clean.
High limit thermostat cycling at too low a
temperature.
Replace thermostat.
Lint door panel not closed properly. Remove lint door panel, place lint door panel back on
tumbler (ensuring a tight fit) then latch.