Service manual
16 M411433
Section 3 Troubleshooting
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the tumbler before servicing.
• Close gas shut-off valve to gas tumbler before servicing.
• Close steam valve to steam tumbler before servicing.
• Never start the tumbler with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be 
reconnected to ensure that the tumbler is properly grounded.
W002
WARNING
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
8. HEATING ELEMENT OR BURNER SHUTS-OFF PREMATURELY
9. HEATING ELEMENT OR BURNER REPEATEDLY CYCLES OFF ON HIGH LIMIT 
THERMOSTAT
POSSIBLE CAUSE TO CORRECT
Improper or inadequate exhaust and/or make-up air 
system.
• Refer to Installation Manual (supplied with tumbler) for 
exhaust and make-up air requirements.
Gas Models: Insufficient gas supply • Open partially closed gas shut-off valve, or correct low 
pressure.
Gas Models: Tumbler not properly equipped for 
type of gas used.
• Tumbler is equipped for type of gas specified on serial 
plate. If orifices are different from that specified on serial 
plate, obtain and install proper orifices.
Gas Models: Improperly adjusted burner flame. • Refer to Adjustment Section for burner flame adjustment.
Gas Models: (Glow-Bar Ignition) Sensor contact 
closing.
• Replace sensor.
Cycling off on limit thermostat. • Refer to Paragraph 9.
Broken, loose or incorrect wiring. • Refer to wiring diagram located on back of tumbler or in 
literature packet.
POSSIBLE CAUSE TO CORRECT
External exhaust system is longer than 
recommended or inadequate make-up air.
• Refer to Installation Manual (supplied with tumbler) for 
exhaust and make-up air requirements.
Clogged lint screen. • Remove screen and clean. Lint screen and compartment 
should be cleaned after every eight hour shift.
Lint in tumbler ducts. • Clean tumbler ducts
Lint in external exhaust system. • Disassemble exhaust system and clean.
High limit thermostat cycling at too low a 
temperature.
• Replace thermostat.
Lint door panel not closed properly. • Remove lint door panel, place lint door panel back on 
tumbler (ensuring a tight fit) then latch.