Service manual

M411433 13
Section 3 Troubleshooting
To reduce the risk of electric shock, fire, explosion, serious injury or death:
Disconnect electric power to the tumbler before servicing.
Close gas shut-off valve to gas tumbler before servicing.
Close steam valve to steam tumbler before servicing.
Never start the tumbler with any guards/panels removed.
Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the tumbler is properly grounded.
W002
WARNING
© Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT
5. HEATING ELEMENT DOES NOT HEAT OR BURNER DOES NOT IGNITE
POSSIBLE CAUSE TO CORRECT
Improper or inadequate exhaust system. Refer to the Installation Manual (supplied with tumbler)
for exhaust system requirements.
Blown fuses or tripped circuit breakers. Check fuses or circuit breakers.
Drying timer not selected or inoperative. Set drying timer or replace if inoperative.
Inoperative thermostat. Test thermostat and replace if inoperative.
Electric Models:
Inoperative heating elements.
Check heat contactors and elements. Replace if necessary.
Gas Models:
Insufficient gas supply.
Open partially closed gas shut-off valve, or correct low
gas pressure. Check inlet pressure and compare to
pressure specified on serial plate. If pressure cannot be
obtained, contact gas supplier.
Gas Models:
Incorrect orifices.
Tumbler is equipped for type of gas specified on serial
plate. If orifices are different from that specified on serial
plate, obtain and install proper orifices.
Gas Models: (IEI Ignition)
Inoperative igniter.
Test igniter and replace if inoperative.
Gas Models: (IEI Ignition)
Inoperative igniter control.
Test igniter control and replace if inoperative.
Gas Models:
Inoperative Main Coil
Test main coil and replace if inoperative.
Gas Models:
Inoperative Redundant Coil
Test redundant coil and replace complete gas valve if
inoperative.
Gas Models: (Glow Bar Ignition)
Inoperative igniter.
Test igniter and replace if inoperative.
Gas Models: (Glow Bar Ignition)
Inoperative sensor.
Test sensor and replace if inoperative.
Gas and Electric Models:
Inoperative high limit thermostat.
Test thermostat and replace if inoperative.
(continued on next page)