Section 3 Troubleshooting
To reduce the risk of electric shock, fire, explosion, serious injury or death:
Disconnect electric power to the tumbler before servicing.
Close gas shut-off valve to gas tumbler before servicing.
Close steam valve to steam tumbler before servicing.
Never start the tumbler with any guards/panels removed.
Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the tumbler is properly grounded.
W002
WARNING
© Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT
2. MOTOR OVERLOAD PROTECTOR CYCLES REPEATEDLY
3. MOTOR RUNS BUT CYLINDER DOES NOT TURN
4. MOTOR DOES NOT STOP
POSSIBLE CAUSE TO CORRECT
Incorrect voltage. Refer to the Installation Manual (supplied with tumbler)
for electrical requirements.
Clothes load too large. Remove part of load.
Cylinder is binding. Check cylinder for binding. Refer to Adjustment Section
for cylinder adjustment.
Inadequate wiring. Check with electrician to ensure that wiring is adequate.
Inadequate make-up air. Refer to Installation Manual (supplied with tumbler) for
make-up air requirements.
Poor housekeeping. Clean lint accumulation on and around the motor.
Broken, loose, or incorrect wiring. Refer to wiring diagram located on back of tumbler or in
literature packet.
POSSIBLE CAUSE TO CORRECT
Motor drive pulley loose. Tighten setscrews.
Sheave loose. Tighten setscrews.
Broken or loose belt. Replace or adjust belt. Refer to Adjustment Section for
proper belt adjustment.
Broken or loose drive chain. Replace or adjust chain. Refer to Adjustment Section for
proper chain adjustment.
Cylinder is binding. Check cylinder for binding. Refer to Adjustment Section
for proper cylinder adjustment.
POSSIBLE CAUSE TO CORRECT
Inoperative door switch or switch is out-of-
adjustment.
Test switch and replace if inoperative. Refer to
Adjustment Section for proper switch adjustment.
Non-Metered Models: Inoperative timer. Test timer and replace if inoperative.
Metered Models: Inoperative accumulator. Test accumulator and replace if inoperative.
Incorrect wiring. Refer to wiring diagram located on the back of tumbler or
in literature packet.