Setting Machine Configurations
(cont.)
Machine Type Options Vended Machines with 4 Compartment Supply Dispenser.
X18R1C
X30R1C
X35R1C
X45R1C
d. Units: Select English or Metric.
e. Level hysteresis: Select the level at which the water drops before it senses it must refill
(e.g. 1 inch [3 cm]) +/- requested water level due to over/undershoot of fill. This avoids
overactive cycling of the water valves.
f. Temperature hysteresis: Select the level at which the temperature drops before it senses it
must increase the temperature (e.g. 4°F [2°C]).
g. Heat: Select correct kw total as listed on machines serial plate or manual.
h. Flow rate: Set the water inlet valves’ average flow rate.
i. Cold inlet temperature: Set the temperature of the cold water supply.
j. Hot inlet temperature: Set the temperature of the hot water supply.
In & Out
a. Drain 1: Standard setting is Valve. Pump is for external pumps by others.
b. Drain 2: Standard setting is No Drain. Drain 2 is used for machines equipped with second
drain option for reuse. Pump is for external pumps by others.
c. Inlet options: Aux Fill & Hard Fill is not selected as standard. If required click on appropriate
selection.
Behavior
a. Advance: When selected, allows operator to fast advance through cycle when selected. Click
to disable fast advance.
b. Spin retries: The amount of tries an out of balance load will be redistributed for proper
balance. This option applies to OPL models only.
c. Chem hold: Standard not selected. This is used on special dispensers that service multiple
machines from one dispenser. Delays cycle progress until dispersing is confirmed.
This option applies to OPL models only.
d. Temperature: Displays or hides the temperature. This option applies to Vended models only.