Installation manual

504522
25
Location Requirements . . .
Select a location with a solid floor.
No other fuel burning appliance should be installed in the
same closet with the dryer.
The dryer must not be installed or stored in an area where
it will be exposed to water and/or weather.
Leveling legs can be adjusted from inside the dryer with
a 1/4" driver. All four legs must rest firmly on the floor so
the weight of the dryer is evenly distributed. The dryer
must not rock.
The dryer needs sufficient clearance and an adequate air
supply for proper operation and ventilation, and for easier
installation and servicing. (Minimum clearances are
shown below.)
CLOSET
DOOR
D337IE3A
FRONT VIEW
(w/o Closet Door)
SIDE VIEW
A
AC
A
D
E
B
CENTERED
AIR
OPENINGS (G)
(2 Openings
Minimum)
FRONT VIEW
(Closet Door)
F
F
OUTER
WALL OF
ENCLOSURE
**42"
** NOTE: For new installations, locate top of wall vent 42 inches above floor to make venting easier to
connect.
AREA DESCRIPTION FREE STANDING /
ALCOVE INSTALLATION
(See Illustration)
CLOSET INSTALLATION
(See Illustration)
A
Dryer sides and rear clearance 0" (0 cm) 0" (0 cm)
B
Dryer top clearance 12" (30.5 cm) 12" (30.5 cm)
C
Dryer front clearance Not Applicable 2" (5.1 cm)
D
Exhaust duct clearance to
combustible material
2" (5.1 cm) 2" (5.1 cm)
E
Weather hood to ground
clearance
12" (30.5 cm) 12" (30.5 cm)
F
Distance from floor or ceiling
to hole edge
Not Applicable 3" (7.6 cm)
G*
Area of centered air openings
in closet door
Not Applicable 40 sq. in./open (260 sq. cm)
*Louvered door with equivalent air openings is acceptable. (Minimum clearances are shown.)