Specifications

Installation
55
F8429301ENR9
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
80 Pound Capacity Models
Voltage Designation Standard Electric Heat
Code
Voltage
Cycle
Phase
Wire
Full Load
Amps
Circuit
Breaker
AWG
mm
2
Full Load
Amps
Circuit
Breaker
AWG
mm
2
F-Speed Models
X 220 – 240 60 1/3 2/3 12/8 15 14 2.5 N/A
Q 220 – 240 60 3 3 8 15 14 2.5 72 80 4 25.0
N 440 – 480 60 3 3 5 15 14 2.5 37 40 8 10.0
P 380 – 415 50 3 3 5 15 14 2.5 33 40 8 10.0
V-Speed Models
X 220 – 240 60 1/3 2/3 15/9 20/15 12/14 4/2.5 N/A
Q 220 – 240 60 3 3 9 15 14 2.5 72 80 4 25.0
N 440 – 480 60 3 3 6 15 14 2.5 37 40 8 10.0
P 380 – 415 50 3 3 6 15 14 2.5 33 40 8 10.0
NOTE: Wire sizes shown are for copper, THHN, 90°C conductor per NEC article 310.
Table 25
100 Pound Capacity Models
Voltage Designation Standard Electric Heat
Code
Voltage
Cycle
Phase
Wire
Full Load
Amps
Circuit
Breaker
AWG
mm
2
Full Load
Amps
Circuit
Breaker
AWG
mm
2
F-Speed Models
X 220 – 240 60 1/3 2/3 16/9 20/15 12/14 4/2.5 N/A
Q 220 – 240 60 3 3 9 15 14 2.5 74 80 4 25.0
N 440 – 480 60 3 3 6 15 14 2.5 37 40 8 10.0
P 380 – 415 50 3 3 6 15 14 2.5 34 40 8 10.0
V-Speed Models
X 220 – 240 60 1/3 2/3 16/10 20/15 12/14 4/2.5 N/A
Q 220 – 240 60 3 3 10 15 14 2.5 74 80 4 25.0
N 440 – 480 60 3 3 7 15 14 2.5 37 40 8 10.0
P 380 – 415 50 3 3 7 15 14 2.5 34 40 8 10.0
NOTE: Wire sizes shown are for copper, THHN, 90°C conductor per NEC article 310.
Table 26