Specifications
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Installation
F8429301ENR9
34
Elevated Pad Installation with Existing
Floor
The existing floor slab must meet minimum
requirements shown in Tabl e 13 per machine. The
floor must be reinforced concrete without voids under
slab. If the slab meets these requirements and an
elevated pad is desired, refer to Figures 21, 24, 33, and
36 and proceed to Machine Foundation and Pad
Installation section.
Elevated Base Frame Installation with
Existing Floor
The existing floor slab must meet minimum
requirements shown in Tabl e 13 per machine. The
floor must be reinforced concrete without voids under
slab. If the slab meets these requirements and an
elevated base frame is desired, refer to Figures 19, 20,
22, 23, 25, 26 and 28 and proceed to Machine
Mounting and Grouting section.
Figure 19
New Foundation
If the existing floor slab does not meet the single
machine foundation requirements per model, refer to
Figures 22, 25, 34, and 37 and proceed to Machine
Foundation and Pad Installation section.
Isolated Pad Installation
This type of installation is NOT recommended.
Installer MUST consult a Structural Engineer for
concrete specifications and requirements for
installations that will not be tied into adjacent
foundations.
IMPORTANT: The above instructions and
recommendations are conservative specifications
for a typical installation based on consultations
with a structural engineer. Alliance Laundry
Systems stands behind all installations meeting
these specifications. For alternate installation
specifications based on your soil type, location,
building structure, unique floor geometry, machine
types, and utilities, consult a structural engineer in
your local area.
CHM2412N