Cabinet Hardmount Refer to Page 5 for Model Identification Installation Washer-Extractors CFD796N_SVG Original Instructions Keep These Instructions for Future Reference. (If this machine changes ownership, this manual must accompany machine.) www.alliancelaundry.com Part No.
Table of Contents Safety Information..................................................................................5 Explanation of Safety Messages....................................................................... 5 Important Safety Instructions........................................................................... 5 Safety Decals................................................................................................. 6 Introduction.......................................................
Disposal of Unit.................................................................................... 63 4 © Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT Part No.
Safety Information Safety Information Explanation of Safety Messages • Precautionary statements [“DANGER,” “WARNING,” and “CAUTION”], followed by specific instructions, are found in this manual and on machine decals. These precautions are intended for the personal safety of the operator, user, servicer, and those maintaining the machine. • DANGER • Indicates an imminently hazardous situation that, if not avoided, will cause severe personal injury or death.
Safety Information warnings or precautions. To reduce the risk of poisoning or chemical burns, keep them out of the reach of children at all times [preferably in a locked cabinet]. Do not use fabric softeners or products to eliminate static unless recommended by the manufacturer of the fabric softener or product. Always follow the fabric care instructions supplied by the textile manufacturer. Loading door MUST BE CLOSED any time the washer is to fill, tumble or spin.
Introduction Introduction Model Identification Information in this manual is applicable to these models: CH018 CHG150 CHR075 CHW305 IH025 IHG150 CH025 CHG165 CHR090 CHW400 IH030 IHG165 CH040 CHG185 CHU065 CHY018 IH040 IHG185 CH055 CHG235 CHU075 CHY025 IH055 IHG235 CH075 CHG305 CHU100 CHY040 IH075 IHG305 CH090 CHG400 CHU135 CHY055 IH090 IHG400 CHE014 CHN065 CHU150 CHY075 IHA065 IHN065 CHE018 CHN075 CHU165 CHY090 IHA075 IHN075 CHE025 CHN100 CHU185 CHZ065 IH
Introduction IHR014 IHW150 IHZ185 WD150 IHR018 IHW165 IHZ235 WD165 IHR025 IHW185 IHZ305 WD185 IHR030 IHW235 IHZ400 WD235 IHR040 IHW305 PHU065 WD305 IHR055 IHW400 PHU075 WD400 IHR075 IHY014 PHU100 YHG065 IHR090 IHY018 PHU135 YHG075 IHU065 IHY025 PHU150 YHG100 IHU075 IHY030 PHU165 YHG135 IHU100 IHY033 PHU185 YHG150 IHU135 IHY035 PHU235 YHG165 IHU150 IHY040 PHU305 YHG185 IHU165 IHY055 PHU400 YHG235 IHU185 IHY075 SH018 YHG305 IHU235 IHY090 SH025 YH
Introduction Nameplate Location The nameplate is located at the rear of the machine. Always provide the machine’s serial number and model number when ordering parts or when seeking technical assistance. Refer to Figure 1 . 1 CFD900N_SVG 1.
Specifications and Dimensions Specifications and Dimensions Specifications and Dimensions General Specifications Capacity lb. (l) 14 (65) 18 (75) 25 (100) 30 (135) 33 (150) 35 (165) Overall width 25.98 in. [660 mm] 25.98 in. [660 mm] 25.98 in. [660 mm] 30.71 in. [780 mm] 30.71 in. [780 mm] 30.71 in. [780 mm] Overall height 41.65 in. [1058 mm] 41.65 in. [1058 mm] 41.65 in. [1058 mm] 47.95 in. [1218 mm] 47.95 in. [1218 mm] 47.95 in. [1218 mm] Overall depth 31.30 in. [795 mm] 31.30 in.
Specifications and Dimensions General Specifications Capacity lb. (l) 14 (65) 18 (75) 25 (100) 30 (135) 33 (150) 35 (165) Door Opening Information Door opening diameter 11.81 in. [300 mm] 11.81 in. [300 mm] 11.81 in. [300 mm] 15.75 in. [400 mm] 15.75 in. [400 mm] 15.75 in. [400 mm] Height of door bottom above floor 11.22 in. [285 mm] 11.22 in. [285 mm] 11.22 in. [285 mm] 12.01 in. [305 mm] 11.61 in. [295 mm] 12.01 in.
Specifications and Dimensions General Specifications Capacity lb. (l) 14 (65) 18 (75) 25 (100) 30 (135) 33 (150) 35 (165) Vibration safety switch installed* NO NO NO NO NO Vibration safety switch installed** NO NO NO YES YES NO YES Direct Steam Heating (Optional) Steam inlet connection size 1 x 3/8 in. 1 x 3/8 in. 1 x 3/8 in. 1 x 3/8 in. 1 x 3/8 in. 1 x 3/8 in.
Specifications and Dimensions General Specifications Capacity lb. (l) Shipping volume 40 (185) 55 (235) 75 (305) 90 (400) 42.82 ft³ [1.21 m³] 61.94 ft³ [1.75 m³] 76.76 ft³ [2.17 m³] 87.86 ft³ [2.49 m³] Wash Cylinder Information Cylinder diameter 26.77 in. [680 mm] Cylinder depth 29.53 in. [750 mm] 19.69 in. [500 mm] 33.46 in. [850 mm] 20.87 in. [530 mm] 33.46 in. [850 mm] 21.14 in. [537 mm] 27.83 in. [707 mm] Cylinder volume 6.4 ft3 [181 l] 8.3 ft3 [234 l] 10.7 ft3 [304 l] 14.
Specifications and Dimensions General Specifications Capacity lb. (l) 40 (185) 55 (235) 75 (305) 90 (400) Centrifugal Force Data Wash/reverse centrifugal force 0.04 - 0.95 0.04 - 1.00 0.05 - 1.00 0.05 - 1.
Specifications and Dimensions Y 6 1 Z AA 2 4 3 P 5 9 8 7 A 11 B U Q AK AL R X S 10 T C D I H E F J GO M K L N V CFD747N_SVG CFD746N_SVG W CFD767N_SVG 14 LB. (65 L), 18 LB. (75 L) AND 25 LB. (100 L) CAPACITY MODELS 1. Fill and Supply Ventilation 2. Direct Fill (Optional) 3. Hot Water Inlet 4. Cold Water Inlet 5. Flushing Supply Dispenser 6. External Liquid Supply Inlets 7. Electrical Steam Input 8. External Supply Signal Input 9. Electrical Power Input 10. Drain Outlet 11.
Specifications and Dimensions Machine Capacity lb. (l) 16 14 (65) 18 (75) 25 (100) inch [mm] inch [mm] inch [mm] E 21.65 [550] 21.65 [550] 21.65 [550] F 25.98 [660] 25.98 [660] 25.98 [660] G 2.17 [55] 2.17 [55] 2.17 [55] H 2.17 [55] 2.17 [55] 2.17 [55] I 1.77 [45] 1.77 [45] 1.77 [45] J 10.75 [273] 9.17 [233] 9.17 [233] K 11.3 [287] 12.87 [327] 16.81 [427] L 1.77 [45] 1.77 [45] 1.77 [45] M 25.59 [650] 25.59 [650] 29.53 [750] N 31.30 [795] 31.30 [795] 35.
Specifications and Dimensions Machine Capacity lb. (l) 14 (65) 18 (75) 25 (100) inch [mm] inch [mm] inch [mm] V 7.09 [180] 7.09 [180] 7.09 [180] W 2.95 [75] 2.95 [75] 2.95 [75] X 27.56 [700] 27.56 [700] 27.56 [700] Y 12.40 [315] 12.40 [315] 12.40 [315] Z 11.61 [295] 11.61 [295] 11.61 [295] AA 9.06 [230] 9.06 [230] 9.06 [230] AK 8.27 [210] 8.27 [210] 8.27 [210] AL 11.42 [290] 11.42 [290] 11.42 [290] Table 3 Part No.
Specifications and Dimensions Y 6 1 2 Z AA 4 3 9 8 7 P 5 AK AL A U Q B R S X 10 T C D I H G E F O J K M L 11 W V N CFD748N_SVG CFD768N_SVG CFD756N_SVG 30 LB. (135 L) AND 35 LB. (165 L) CAPACITY MODELS 1. Fill and Supply Ventilation 2. Direct Fill (Optional) 3. Hot Water Inlet 4. Cold Water Inlet 5. Flushing Supply Dispenser 6. External Liquid Supply Inlets 7. Electrical Steam Input 8. External Supply Signal Input 9. Electrical Power Input 10. Drain Outlet 11.
Specifications and Dimensions Machine Capacity lb. (l) Part No. D1341ENR8 30 (135) 35 (165) inch [mm] inch [mm] D 12.01 [305] 12.01 [305] E 25.20 [640] 25.20 [640] F 30.71 [780] 30.71 [780] G 2.76 [70] 2.76 [70] H 2.76 [70] 2.76 [70] I 1.10 [28] 1.10 [28] J 10.24 [260] 10.24 [260] K 16.14 [410] 20.08 [510] L 1.10 [28] 1.10 [28] M 28.58 [726] 32.52 [826] N 34.65 [880] 38.58 [980] O 2.56 [65] 2.56 [65] P 3.74 [95] 3.74 [95] Q 42.72 [1085] 42.72 [1085] R 37.
Specifications and Dimensions Machine Capacity lb. (l) 30 (135) 35 (165) inch [mm] inch [mm] U 1.38 [35] 1.38 [35] V 7.87 [200] 7.87 [200] W 3.74 [95] 3.74 [95] X 33.66 [855] 33.66 [855] Y 13.98 [355] 13.98 [355] Z 13.19 [335] 13.19 [335] AA 10.63 [270] 10.63 [270] AK 8.27 [210] 8.27 [210] AL 11.42 [290] 11.42 [290] Table 4 20 © Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT Part No.
Specifications and Dimensions Y 6 1 P 5 2 Z AA 4 3 9 8 7 AK AL Q A U R B X S 10 T C D I J H GO E F L K M 11 N V CFD769N_SVG CFD757N_SVG W CFD758N_SVG 33 LB. (150 L) AND 40 LB. (185 L) CAPACITY MODELS 1. Fill and Supply Ventilation 2. Direct Fill (Optional) 3. Hot Water Inlet 4. Cold Water Inlet 5. Flushing Supply Dispenser 6. External Liquid Supply Inlets 7. Electrical Steam Input 8. External Supply Signal Input 9. Electrical Power Input 10. Drain Outlet 11.
Specifications and Dimensions Machine Capacity lb. (l) 22 33 (150) 40 (185) inch [mm] inch [mm] E 25.20 [640] 25.20 [640] F 30.71 [780] 30.71 [780] G 2.76 [70] 2.76 [70] H 2.76 [70] 2.76 [70] I 1.10 [28] 1.10 [28] J 10.24 [260] 10.24 [260] K 16.14 [410] 20.08 [510] L 1.10 [28] 1.10 [28] M 28.58 [726] 32.52 [826] N 34.65 [880] 38.58 [980] O 2.56 [65] 2.56 [65] P 3.74 [95] 3.74 [95] Q 42.72 [1085] 42.72 [1085] R 37.80 [960] 37.80 [960] S 35.43 [900] 35.
Specifications and Dimensions Machine Capacity lb. (l) 33 (150) 40 (185) inch [mm] inch [mm] V 7.87 [200] 7.87 [200] W 3.74 [95] 3.74 [95] X 33.66 [855] 33.66 [855] Y 14.02 [356] 13.98 [355] Z 13.19 [335] 13.19 [335] AA 10.63 [270] 10.63 [270] AK 8.27 [210] 8.27 [210] AL 11.42 [290] 11.42 [290] Table 5 Part No.
Specifications and Dimensions 2 Y 3 Z AA P 1 4 5 7 8 6 9 AK AL A B 11 U Q X R 10 S C T D I H GO E F J K M L V N CFD906N_SVG CFD760N_SVG CFD759N_SVG W 55 LB. (235 L) CAPACITY MODELS 1. Flushing Supply Dispenser 2. Fill and Supply Ventilation 3. External Liquid Supply Inlets 4. Direct Fill (Optional) 5. Cold Water Inlet 6. Hot Water Inlet 7. Electrical Power Input 8. External Supply Signal Input 9. Electrical Steam Input 10. Drain Outlet 11.
Specifications and Dimensions Machine Capacity lb. (l) 55 (235) inch [mm] Part No. D1341ENR8 E 26.77 [680] F 33.86 [860] G 3.54 [90] H 3.54 [90] I 1.97 [50] J 11.10 [282] K 20.39 [518] L 1.97 [50] M 35.43 [900] N 41.14 [1045] O 2.56 [65] P 3.94 [100] Q 49.21 [1250] R 44.29 [1125] S 41.93 [1065] T 22.64 [575] U 1.
Specifications and Dimensions Machine Capacity lb. (l) 55 (235) inch [mm] V 7.87 [200] W 3.74 [95] X 39.96 [1015] Y 14.57 [370] Z 13.78 [350] AA 11.22 [285] AK 8.46 [215] AL 11.61 [295] Table 6 26 © Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT Part No.
Specifications and Dimensions P 1 A B C D O H J I G E N CFD770N_SVG CFD762N_SVG AN 2 AM Y Z AA 3 L K M F 4 5 7 8 6 9 10 11 AK AL Q R 13 AO S X U 12 T V W CFD871N_SVG 75 LB. (305 L) AND 90 LB. (400 L) CAPACITY MODELS 1. Flushing Supply Dispenser 2. Fill and Supply Ventilation 3. External Liquid Supply Inlets 4. Direct Fill (Optional) 5. Cold Water Inlet 6. Hot Water Inlet 7. Cold Water Inlet 8. Hot Water Inlet 9. Electrical Power Input 10. External Supply Signal Input 11.
Specifications and Dimensions Machine Capacity lb. (l) 28 75 (305) 90 (400) inch [mm] inch [mm] A 55.83 [1418] 55.83 [1418] B 54.72 [1390] 54.72 [1390] C 19.49 [495] 19.49 [495] D 15.75 [400] 15.75 [400] E 33.46 [850] 33.46 [850] F 38.98 [990] 38.98 [990] G 2.76 [70] 2.76 [70] H 2.76 [70] 2.76 [70] I 2.60 [66] 2.60 [66] J 13.66 [347] 13.66 [347] K 22.44 [570] 29.13 [740] L 1.85 [47] 1.85 [47] M 40.55 [1030] 47.24 [1200] N 45.67 [1160] 52.36 [1330] O 2.
Specifications and Dimensions Machine Capacity lb. (l) 75 (305) 90 (400) inch [mm] inch [mm] S 43.31 [1100] 43.31 [1100] T 17.13 [435] 17.13 [435] U 1.38 [35] 1.38 [35] V 10.83 [275] 10.83 [275] W 3.74 [95] 3.74 [95] X 41.14 [1045] 41.14 [1045] Y 15.16 [385] 15.16 [385] Z 14.37 [365] 14.37 [365] AA 11.81 [300] 11.81 [300] AK 8.46 [215] 8.46 [215] AL 11.61 [295] 11.61 [295] AM 18.50 [470] 18.50 [470] AN 20.08 [510] 20.08 [510] AO 46.85 [1190] 46.
Installation Installation Dimensional Clearances Table 8 and Table 9 show recommended minimum clearances on all sides of the machine. Recommended Minimum Clearances - 14 lb. (65 l), 18 lb. (75 l), 25 lb. (100 l), 30 lb. (135 l) and 33 lb. (150 l) Models Capacity lb. (l) 14 (65) 18 (75) 25 (100) 30 (135) 33 (150) Minimum rear clearance 24 in. [600 mm] 24 in. [600 mm] 24 in. [600 mm] 24 in. [600 mm] 24 in. [600 mm] Minimum clearance between machine and wall 6 in. [150 mm] 6 in. [150 mm] 6 in.
Installation Recommended Minimum Clearances - 35 lb. (165 l), 40 lb. (185 l), 55 lb. (235 l), 75 lb. (305 l) and 90 lb. (400 l) Models Capacity lb. (l) Minimum front clearance (door swing) 35 (165) 40 (185) 22.05 in. [560 mm] 55 (235) 22.05 in. [560 mm] 75 (305) 22.05 in. [560 mm] 90 (400) 22.05 in. [560 mm] 22.05 in.
Installation Floor Load Data - 35 lb. (165 l), 40 lb. (185 l), 55 lb. (235 l), 75 lb. (305 l) and 90 lb. (400 l) Models Capacity lb. (l) 35 (165) 40 (185) 55 (235) 75 (305) 90 (400) Kinetic Energy of the Cylinder, (N/m)* 7215 8840 12677 17253 21613 Kinetic Energy of the Cylinder, (N/ m)** 12429 17431 24847 34046 N/A Dynamic Bottom Load, (N/Hz)* 2968/8 3348/7.8 4235/7.5 5520/7 7240/7 Dynamic Bottom Load, (N/Hz)** 5249/10.5 6738/11 8522/10.5 11072/9.
Installation Machine Capacity lb. (l) 14 (65) 18 (75) inch [mm] 25 (100) inch [mm] inch [mm] AB 1.18 [30] 1.18 [30] 1.18 [30] AC 21.65 [550] 21.65 [550] 21.65 [550] AD 23.94 [608] 23.94 [608] 23.94 [608] AE 1.18 [30] 1.18 [30] 1.18 [30] AF 1.77 [45] 1.77 [45] 1.77 [45] AG 9.17 [233] 9.17 [233] 9.17 [233] AH 12.87 [327] 12.87 [327] 16.81 [427] AI 1.77 [45] 1.77 [45] 1.77 [45] AJ 0.71 [18] 0.71 [18] 0.
Installation Machine Capacity lb. (l) 30 (135) 35 (165) in [mm] in [mm] AB 1.73 [44] 1.73 [44] AC 25.20 [640] 25.20 [640] AD 28.62 [727] 28.62 [727] AE 1.73 [44] 1.73 [44] AF 1.10 [28] 1.10 [28] AG 10.24 [260] 10.24 [260] AH 16.14 [410] 20.08 [510] AI 1.10 [28] 1.10 [28] AJ 0.87 [22] 0.87 [22] Table 13 34 © Copyright, Alliance Laundry Systems LLC - DO NOT COPY or TRANSMIT Part No.
Installation Mounting Bolt Hole Locations for Hardmount Models with 33 lb. (150 l), 40 lb. (185 l), 55 lb. (235 l), 75 lb. (305 l) and 90 lb. (400 l) Capacity AI AJ AH AG AF AC AB AD AE CFD858N_SVG Figure 9 Machine Capacity lb. (l) 33 (150) in [mm] 40 (185) in [mm] 55 (235) in [mm] 75 (305) in [mm] 90 (400) in [mm] AB 1.73 [44] 1.73 [44] 2.28 [58] 1.57 [40] 1.57 [40] AC 25.20 [640] 25.20 [640] 26.77 [680] 33.46 [850] 33.46 [850] AD 28.62 [727] 28.62 [727] 31.34 [796] 36.
Installation Machine Capacity lb. (l) 33 (150) AJ 0.87 [22] 40 (185) 55 (235) 0.87 [22] 75 (305) 0.87 [22] 90 (400) 0.87 [22] 0.87 [22] Table 14 Mounting Bolt Installation (If Required) CAUTION Ensure that the machine is installed on a level floor of sufficient strength and that the recommended clearances for inspection and maintenance are provided. Never allow the inspection and maintenance space to be blocked. W488 Models with 14 lb. (65 l), 18 lb. (75 l), 25 lb. (100 l), 30 lb.
Installation 5 4 6 3 4 3 7 2 8 1 CFD689N_SVG 1. Bolt 1/2 in. [M12] [14 lb. (65 l), 18 lb. (75 l), 25 lb. (100 l)],(30 lb. [135 l] 5/8 in. [M16], 35 lb. [165 l]) 2. Concrete base: Refer to Table 15 . 3. Washer 1.57x0.60x0.15 in. [40x17x4 mm] 4. Nut 1/2 in. [M12] (14 lb. [65 l], 18 lb. [75 l], 25 lb. [100 l]), (30 lb. [135 l] 5/8 in. [M16], 35 lb. [165 l]) 5. Base of the machine 6. Metal base 7. Bolt 5/8 in. x 2-1/2 in. [M16x60] 8. Grout Figure 11 Capacity Minimum foundation thickness 14 lb.
Installation 3 4 5 2 6 1 CFD690N_SVG 1. Bolt 1/2 in. [M12] (14 lb. [65 l], 18 lb. [75 l], 25 lb. [100 l] and 30 lb. [135 l]); 5/8 in. [M16] (35 lb. [165 l]) 2. Concrete base: Refer to Table 15 . 3. Base of the machine 4. Nut 1/2 in. [M12] (14 lb. [65 l], 18 lb. [75 l], 25 lb. [100 l] and 30 lb. [135 l]); 5/8 in. [M16] (35 lb. [165 l]) 5. Washer 1.57x0.60x0.15 in. [40x17x4 mm] 6.
Installation Capacity Minimum foundation thickness Low Speed * Medium Speed ** 33 lb. (150 l) 40 lb. (185 l) 55 lb. (235 l) 75 lb. (305 l) 90 lb. (400 l) 4 in. [102 mm] 6 in. [152 mm] 6 in. [152 mm] 8 in. [203 mm] 8 in. [203 mm] 16 in. [406 n/a 12 in. [305 mm] 12 in. [305 mm] 16 in. [406 mm] mm] Table 16 * For models with L in the 9th position (***075YELXWDG) of the manufacturing model number.
Installation Increasing the drain hose length, installing elbows, or causing bends will impair machine performance. Refer to Table 17 and Table 18 for capacity-specific drain information. NOTE: Installation of additional machines will require proportionately larger drain connections. Refer to Table 19 . Drain Information - Models 14 lb. (65 l), 18 lb. (75 l), 25 lb. (100 l), 30 lb. (135 l) and 33 lb. (150 l) Models Capacity lb.
Installation Drain Line SizingMinimum Drain ID Number of Machines Capacity lb. (l) 1 2 3 4 5 6 7 14 (65) 2 in. [50.8 mm] 3 in. [76.2 mm] 3.5 in. [88.9 mm] 4 in. [101.6 mm] 4.5 in. [114.3 mm] 5 in. [127 mm] 5.5 in. [139.7 mm] 18 (75) 2 in. [50.8 mm] 3 in. [76.2 mm] 3.5 in. [88.9 mm] 4 in. [101.6 mm] 4.5 in. [114.3 mm] 5 in. [127 mm] 5.5 in. [139.7 mm] 25 (100) 2 in. [50.8 mm] 3 in. [76.2 mm] 3.5 in. [88.9 mm] 4 in. [101.6 mm] 4.5 in. [114.3 mm] 5 in. [127 mm] 5.5 in. [139.
Installation Water Connection 1. Before installing hoses, flush the water system for at least two minutes. 2. Check filters in the machine’s inlet hoses for proper fit and cleanliness before connecting. 3. For 75 lb. (305 l) and 90 lb. (400 l) models only, attach the Yconnector, which is included with the machine, to the faucets prior to connecting the water inlet hoses. Refer to 75 LB. (305 L) AND 90 LB. (400 L) CAPACITY MODELS.
Installation Water Supply Information - 35 lb. (165 l), 40 lb. (185 l), 55 lb. (235 l), 75 lb. (305 l) and 90 lb. (400 l) Models Capacity lb. (l) 35 (165) 40 (185) 55 (235) 75 (305) 90 (400) Water inlet connection size 3/4 in. [19 mm] 3/4 in. [19 mm] 3/4 in. [19 mm] 3/4 in. [19 mm] 3/4 in. [19 mm] Number of water inlets (standard) 2 2 2 4 4 Recommended pressure 28-85 psi [2-6 bar] 28-85 psi [2-6 bar] 28-85 psi [2-6 bar] 28-85 psi [2-6 bar] 28-85 psi [2-6 bar] Inlet flow capacity 5.
Installation 1 Figure 19 2 5 4 3 Figure 20 6 1 2 CFD859N_SVG 75 LB. (305 L) AND 90 LB. (400 L) CAPACITY MODELS 1. Air Cushions (Risers) 2. Water Supply Faucets 3. Double Check Valves 4. Filters 5. Hoses 6. "Y" Connector (Included with Machine) 6 3 4 5 CFD873N_SVG Figure 18 WRAS Water Connection To comply with WRAS (IRN R150) and Australian water regulations, European standard EN1717 and Australian standard ATS5200.
Installation IMPORTANT: Alliance Laundry Systems warranty does not cover compounds that fail as a result of improper input voltage WARNING Before starting wiring or inspection, power must be switched OFF. Check to make sure that the operation panel indicator is OFF. Any person who is involved in wiring or inspection shall wait for at least 10 minutes after the power supply has been switched OFF and check that there are no residual voltage using a tester or the like.
Installation Electrical Specifications Hot/Cold Water Fill and Steam Heat Voltage Designation Capacity lb. (l) Code Voltage Cycle Phase 14 (65) C 380-415 50/60 3 Wire 3+N +PE Full Load Amps Circuit Breaker U.S. [non U.S.] 4.5 15 [16] AWG [mm2] 14 [2.5] Electric Heat Full Load Amps Heating Element kw (Voltage) 11.60 6Kw (380V) Circuit Breaker U.S. [non U.S.] AWG [mm2] 15 [16] 14 [2.5] 13.40 6Kw (415V) 14 (65) N 440-480 50/60 3 3+PE 2 15 [6] 14 [2.
Installation Electrical Specifications Hot/Cold Water Fill and Steam Heat Voltage Designation Capacity lb. (l) Code Voltage Cycle Phase 18 (75) C 380-415 50/60 3 Wire 3+N +PE Full Load Amps Circuit Breaker U.S. [non U.S.] 4.5 15 [16] AWG [mm2] 14 [2.5] Electric Heat Full Load Amps Heating Element kw (Voltage) 16.20 9Kw (380V) Circuit Breaker U.S. [non U.S.] AWG [mm2] 25 [20] 12 [2.5] 18.80 9Kw (415V) 18 (75) N 440-480 50/60 3 3+PE 2 15 [6] 14 [2.
Installation Electrical Specifications Hot/Cold Water Fill and Steam Heat Voltage Designation Capacity lb. (l) Code Voltage Cycle Phase 25 (100) C 380-415 50/60 3 Wire 3+N +PE Full Load Amps Circuit Breaker U.S. [non U.S.] 4.5 15 [16] AWG [mm2] 14 [2.5] Electric Heat Full Load Amps Heating Element kw (Voltage) 16.20 9Kw (380V) Circuit Breaker U.S. [non U.S.] AWG [mm2] 25 [20] 12 [2.5] 18.80 9Kw (415V) 25 (100) N 440-480 50/60 3 3+PE 2 15 [6] 14 [2.
Installation Electrical Specifications Hot/Cold Water Fill and Steam Heat Voltage Designation Capacity lb. (l) Code Voltage Cycle Phase 30 (135) C 380-415 50/60 3 Wire 3+N +PE Full Load Amps Circuit Breaker U.S. [non U.S.] 6.5 15 [16] AWG [mm2] 14 [2.5] Electric Heat Full Load Amps Heating Element kw (Voltage) 20.8 12Kw (380V) Circuit Breaker U.S. [non U.S.] AWG [mm2] 30 [25] 10 [2.5] 40 [32] 8 [4] 30 [25] 10 [2.5] 40 [40] 8 [4] 24.
Installation Electrical Specifications Hot/Cold Water Fill and Steam Heat Voltage Designation Capacity lb. (l) Code Voltage Cycle Phase 30 (135) X 200-240 50/60 1/3 33 (150) C 380-415 50/60 3 Full Load Amps Circuit Breaker U.S. [non U.S.] 2/3+PE 6.5 15 [16] 14 [2.5] 3+N +PE 6.5 15 [16] 14 [2.5] Wire AWG [mm2] Electric Heat Full Load Amps Heating Element kw (Voltage) Circuit Breaker U.S. [non U.S.] AWG [mm2] N/A 30.
Installation Electrical Specifications Hot/Cold Water Fill and Steam Heat Voltage Designation Capacity lb. (l) Code Voltage Cycle Phase 33 (150) Q 200-240 50/60 3 Wire Full Load Amps Circuit Breaker U.S. [non U.S.] 3+PE AWG [mm2] N/A Electric Heat Full Load Amps Heating Element kw (Voltage) 40.5 18Kw (208V) Circuit Breaker U.S. [non U.S.] AWG [mm2] 60 [63] 6 [10] 52.8 18Kw (240V) 33 (150) X 200-240 50/60 1/3 2/3+PE 6.5 15 [16] 14 [2.
Installation Electrical Specifications Hot/Cold Water Fill and Steam Heat Voltage Designation Capacity lb. (l) Code Voltage Cycle Phase 35 (165) N 440-480 50/60 3 Wire 3+PE Full Load Amps Circuit Breaker U.S. [non U.S.] 2.5 15 [6] AWG [mm2] 14 [2.5] Electric Heat Full Load Amps Heating Element kw (Voltage) 24.9 18Kw (440V) Circuit Breaker U.S. [non U.S.] AWG [mm2] 40 [32] 8 [4] 30 [25] 10 [2.5] 40 [40] 8 [4] 60 [63] 6 [10] 29.
Installation Electrical Specifications Hot/Cold Water Fill and Steam Heat Voltage Designation Capacity lb. (l) Code Voltage Cycle Phase 35 (165) X 200-240 50/60 1/3 40 (185) C 380-415 50/60 3 Full Load Amps Circuit Breaker U.S. [non U.S.] 2/3+PE 6.5 15 [16] 14 [2.5] 3+N +PE 6.5 15 [16] 14 [2.5] Wire AWG [mm2] Electric Heat Full Load Amps Heating Element kw (Voltage) Circuit Breaker U.S. [non U.S.] AWG [mm2] N/A 30.
Installation Electrical Specifications Hot/Cold Water Fill and Steam Heat Voltage Designation Capacity lb. (l) Code Voltage Cycle Phase 40 (185) Q 200-240 50/60 3 Wire Full Load Amps Circuit Breaker U.S. [non U.S.] 3+PE AWG [mm2] N/A Electric Heat Full Load Amps Heating Element kw (Voltage) 40.5 18Kw (208V) Circuit Breaker U.S. [non U.S.] AWG [mm2] 60 [63] 6 [10] 52.8 18Kw (240V) 40 (185) X 200-240 50/60 1/3 2/3+PE 6.5 15 [16] 14 [2.
Installation Electrical Specifications Hot/Cold Water Fill and Steam Heat Voltage Designation Capacity lb. (l) Code Voltage Cycle Phase 55 (235) P 380-415 50/60 3 Wire 3+PE Full Load Amps Circuit Breaker U.S. [non U.S.] 2.5 15 [6] AWG [mm2] 14 [2.5] Electric Heat Full Load Amps Heating Element kw (Voltage) 29 18Kw (380V) Circuit Breaker U.S. [non U.S.] AWG [mm2] 40 [40] 8 [4] 60 [63] 6 [10] 34.20 18Kw (415V) 55 (235) Q 200-240 50/60 3 3+PE N/A 41 18Kw (208V) 53.
Installation Electrical Specifications Hot/Cold Water Fill and Steam Heat Voltage Designation Capacity lb. (l) Code Voltage Cycle Phase 75 (305) N 440-480 50/60 3 Wire 3+PE Full Load Amps Circuit Breaker U.S. [non U.S.] 2.5 15 [6] AWG [mm2] 14 [2.5] Electric Heat Full Load Amps Heating Element kw (Voltage) 25.3 18Kw (440V) Circuit Breaker U.S. [non U.S.] AWG [mm2] 40 [32] 8 [4] 60 [63] 6 [10] 60 [63] 6 [10] 29.8 18Kw (480V) 75 (305) P 380-415 50/60 3 3+PE 2.
Installation Electrical Specifications Hot/Cold Water Fill and Steam Heat Voltage Designation Capacity lb. (l) Code Voltage Cycle Phase 90 (400) C 380-415 50/60 3 Wire 3+N +PE Full Load Amps Circuit Breaker U.S. [non U.S.] 7.5 15 [16] AWG [mm2] 14 [2.5] Electric Heat Full Load Amps Heating Element kw (Voltage) 44.7 24Kw (380V) Circuit Breaker U.S. [non U.S.] AWG [mm2] 60 [63] 6 [10] 40 [32] 8 [4] 60 [63] 6 [10] 60 [63] 6 [10] 51.
Installation Electrical Specifications Hot/Cold Water Fill and Steam Heat Voltage Designation Capacity lb. (l) Code Voltage Cycle Phase 90 (400) X 200-240 50/60 1/3 Wire 2/3+PE Full Load Amps Circuit Breaker U.S. [non U.S.] 7.5 15 [16] AWG [mm2] Electric Heat Full Load Amps Heating Element kw (Voltage) Circuit Breaker U.S. [non U.S.] 14 [2.
Installation A connection has been placed at the back of the machine. There are five holes in this connection, through each of which a liquid supply hose can be connected. Chemical Injection Supply System WARNING Dangerous Chemicals. May damage eyes and skin. Wear eye and hand protection when handling chemicals; always avoid direct contact with raw chemicals. Read the manufacturer’s directions for accidental contact before handling chemicals.
Installation Steam Supply Information 14 (65) , 18 (75), 25 (100), 30 (135), 33 (150), 35 (165), 40 (185) Capacity lb. (l) Maximum pressure, psi [bar] 55 (235), 75 (305), 90 (400) 78 [5.5] 78 [5.5] Table 23 Supply Programming Table When programming a supply step on the WE-8, choose between 9 different supply steps. Refer to Table 24 . Supply 1 Turns on the water valve in compartment A of the supply box. Supply 2 Turns on the water valve in compartment B of the supply box.
Installation Primary 220 Volt Remote Liquid Supply Connection IMPORTANT: When programming a supply step, supplies 1, 2 and 3 DO NOT control the relays shown on Figure 25 . Programming supply 1, 2 or 3 ONLY activates water in compartment A, B or C. Programming supply 4 activates relay 1. Programming supply 5 on the WE-8 will activate supply relay 2, etc. Programming supply 4-9 on the WE-8 will activate supply relay 1-6 on the board, respectively. Refer to Table 24 .
Installation The out-of-balance switch is mounted on the upper right side on the back of the control panel. There is a window around the probe of the switch that is mounted on the movable part of the machine. When the machine goes out of balance by overloading or uneven distribution of the linen, the out-of-balance switch will interrupt this action to prevent damage to the machine.
Disposal of Unit Disposal of Unit This appliance is marked according to the European directive 2002/96/EC on Waste Electrical and Electronic Equipment (WEEE). This symbol on the product or on its packaging indicates that this product shall not be treated as household waste. Refer to Figure 32 . Instead it shall be handed over to the applicable collection point for the recycling of electrical and electronic equipment.