325 mm (13 inch) Roll Models Refer to Page 3 for Model Identification FWF1N Keep These Instructions for Future Reference. (If this machine changes ownership, this manual must accompany machine.) www.comlaundry.com Part No.
Installation/Operation Supplement WARNING FOR YOUR SAFETY, the information in this manual must be followed to minimize the risk of fire or explosion or to prevent property damage, personal injury or death. W033 • Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. • WHAT TO DO IF YOU SMELL GAS: – Do not try to light any appliance. – Do not touch any electrical switch; do not use any phone in your building.
Installation/Operation Supplement Table of Contents Model Identification ........................................................................... 3 Safety Information.............................................................................. 4 Installation........................................................................................... Overall Dimensions and Connecting Data ........................................... Location Requirements................................................
Installation/Operation Supplement Model Identification Information in this manual is applicable to the following models: UD13F063 UD13F078 UD13F079 UD13F126 1300567 (EN) © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT 3
Installation/Operation Supplement Safety Information NOTE: This manual is only a supplement. Refer to Installation/Operation manual for full instructions. WARNING Electrical hazard inside. Can cause death or serious injury. Turn off and lockout/tag out all electrical power before opening. W536 WARNING Moving parts hazard. Can cause serious injury. Do not operate unless all guards and covers are in place. Do not put hands/fingers beyond guard/ cover. W537 WARNING Burn hazards.
Installation/Operation Supplement WARNING • Failure to install, maintain, and/or operate this machine according to the manufacturer’s instructions may result in conditions which can produce serious injury, death, and/or property damage. • Do not repair or replace any part of the machine or attempt any servicing unless specifically recommended or published in this Installation/Operation Manual and that you are qualified to carry out.
Installation/Operation Supplement Installation NOTE: This manual is only a supplement. Refer to Installation/Operation manual for full instructions. IMPORTANT: Warranty is void unless the finisher is installed according to instructions in this manual.
Installation/Operation Supplement Overall Dimensions and Connecting Data Exhaust Duct 102 mm (4 in.) FRONT VIEW Exhaust Duct 102 mm (4 in.) 500 mm (19.68 in.) 500 mm (19.68 in.) Model UD13F063 2192 mm (86 in.) Models UD13F078 and UD13F079 2542 mm (100.1 in.) Model UD13F126 3910 mm (154 in.) REAR VIEW 1112 mm (43.8 in.) 130 mm (5.12 in.) 70 mm (2.76 in.) Gas Inlet and Electric Inlet TOP VIEW 58 mm (2.28 in.) 542 mm (21.34 in.) 60 mm (2.36 in.
Installation/Operation Supplement Model UD13F063 Weight 400 kg (882 lbs.) UD13F078 and UD13F079 420 kg (926 lbs.) UD13F126 500 kg (1102 lbs.) Lifting the Finisher NOTE: This manual is only a supplement. Refer to Installation/Operation manual for full instructions. The finisher should be moved with a forklift as close as possible to the area where it will be installed. Location Requirements NOTE: This manual is only a supplement. Refer to Installation/Operation manual for full instructions.
Installation/Operation Supplement 3. Use the forklift to carefully lift the packaged finisher. Refer to Figure 3. IMPORTANT: DO NOT lift the unit more than 203 mm (8 inches) off the ground. Moving the Finisher with Rollers NOTE: This manual is only a supplement. Refer to Installation/Operation manual for full instructions. IMPORTANT: At least three people and three 89 mm (3.5 inch) to 102 mm (4 inch) rollers or pipes are required to move the finisher from the skid to its final location.
Installation/Operation Supplement 4. Place two rollers on the ground next to the finisher. Refer to Figure 5. 7. Slowly roll the finisher forward. Refer to Figure 6. 5. Place the third roller on the ground ahead of the first two rollers and past the end of the finisher. 6. Slowly lower the finisher off the skid and onto the first two rollers. Keep the unit level. Refer to Figure 5. IMPORTANT: DO NOT let go of the finisher at any point in the moving process.
Installation/Operation Supplement Electrical Connection IMPORTANT: Electrical specifications in Tables 1 and 2 are subject to change without notice. Always refer to product serial plate for most current specifications of product being installed. Electrical connections should be made by a qualified electrical contractor in accordance with all applicable local and national requirements.
Installation/Operation Supplement Gas Connection NOTE: This manual is only a supplement. Refer to Installation/Operation manual for full instructions. IMPORTANT: The installation must comply with local codes or, in the absence of local codes, with the current National Fuel Gas Code, ANSI Z223.1 in the U.S.A., or the current CAN/CSA B149, Installation Codes in Canada. When connecting to a gas line, an equipment shut-off valve must be installed within 1.8 m (6 feet) of the finisher.
Installation/Operation Supplement Gas Technical Specifications Country Gas Category Gas Designation Pressure (mbar) DE I2ELL G20 20 G25 20 I3P G31 50 AT/DK/FI/IT/ SE I2H G20 20 IE/PT/GB/GR II2H3P G20 20 G31 37 CH/ES II2H3P BE I2E+ I3P FR II2Esi3P LU NL II2E3P II2L3P G20 20 G31 37 and 50 G20 20 G25 25 G31 37 G20 20 G25 25 G31 37 and 50 G20 20 G31 50 G25 25 G31 50 1 2 4 D233I 1 2 3 Table 4 4 5 Inlet Pressure Use a manometer to verify that the inlet
Installation/Operation Supplement Gas Conversion NOTE: This manual is only a supplement. Refer to Installation/Operation manual for full instructions. NOTE: DO NOT connect the finisher to L.P. Gas Service without converting the gas valve. An L.P. Gas Conversion kit must be installed by the Manufacturer’s Authorized Dealers, Distributors, or qualified service personnel. NOTE: Instructions for installing gas conversion kit can be found inside left frame of finisher.
Installation/Operation Supplement Exhaust Requirements NOTE: This manual is only a supplement. Refer to Installation/Operation manual for full instructions. NOTE: At a minimum, the National Fuel Gas Code requires finishers to have at least 6.5 sq. cm (one square inch) of opening for every 1000 Btu/hr. of input rating for proper combustion. IMPORTANT: Do not obstruct flow of combustion and ventilation air. WARNING The air flow necessary for combustion is shown in Table 6.
Installation/Operation Supplement First Start-Up 11. Place all panels back on the finisher. 1. Verify that the finisher is stable and level. 12. Turn the heat switch to position 1 (ON). 2. Check that all connections and exhausts are correctly established. 13. Check that the temperature of the finisher rises. 3. Check that the finisher is properly grounded. 4. Remove wax paper from cylinder, if applicable. 5. Inspect thermostat holder and make sure it is touching cylinder.
Installation/Operation Supplement Operation Operating Instructions for Microprocessor Models Operating Controls WARNING WARNING To avoid serious injury BEFORE operating flatwork finisher, ALL personnel MUST be trained on safe operation. To avoid possible serious injury, ALWAYS read and become familiar with operating instructions before operating flatwork finisher.
Installation/Operation Supplement Pre-Operating Procedures NOTE: All maintenance must always be carried out when the machine is stopped, the cylinder is cold, and the circuit breaker is turned off. Perform the following procedures daily before starting the finisher. 1. Inspect the area between the thermostat and the cylinder by gently pressing on the thermostat holder so the thermostat lifts up. 2. Clean area if debris is present. 3. Check that the thermostat holder touches the cylinder.
Installation/Operation Supplement 8. View temperature display. For best performance, begin ironing a few degrees before preset temperature is reached (for example, if preset temperature is 176°C [350°F], begin ironing at 173°C [345°F]). Refer to Installation/Operation manual for information on heating the cylinder. IMPORTANT: The working temperature varies depending on the fabric being ironed but must never exceed a constant temperature of 180°C (356°F). 9.
Installation/Operation Supplement Operating Instructions for Electromechanical Models Operating Controls WARNING WARNING To avoid serious injury BEFORE operating flatwork finisher, ALL personnel MUST be trained on safe operation. To avoid possible serious injury, ALWAYS read and become familiar with operating instructions before operating flatwork finisher.
Installation/Operation Supplement Pre-Operating Procedures NOTE: All maintenance must always be carried out when the machine is stopped, the cylinder is cold, and the circuit breaker is turned off. Perform the following procedures daily before starting the finisher. 1. Inspect the area between the thermostat and the cylinder by gently pressing on the thermostat holder so the thermostat lifts up. 2. Clean area if debris is present. 3. Check that the thermostat holder touches the cylinder.
Installation/Operation Supplement Breakdown Procedures Alarms (Microprocessor Models Only) Hot Finisher Stops Due to Power Failure An alarm will sound for abnormal conditions as shown below. To separate the return ribbons from cylinder immediately: 1. Insert the crank into the opening located on the right panel of the finisher. 2. Turn the crank clockwise to rotate the cylinder. Refer to Figure 11. 3.
Installation/Operation Supplement Thermal Warning Fan Overheating or Sensor Not Connected When the thermal relay of the fan is activated, the alarm sounds for one minute and display shows AL4. The fan and heating are switched off and finisher remains on. This alarm is usually caused by dirt on the fan. If the temperature sensor is broken, not connected or if sensor detects a temperature above 210°C (410°F) continuously for two seconds, the alarm sounds for one minute and display shows AL7.
Installation/Operation Supplement Disposal of Unit This appliance is marked according to the European directive 2002/96/EC on Waste Electrical and Electronic Equipment (WEEE). This symbol on the product or on its packaging indicates that this product shall not be treated as household waste. Refer to Figure 12. Instead it shall be handed over to the applicable collection point for the recycling of electrical and electronic equipment.