User guide
Allen & Heath     20     XONE:S2 User 
MASTER SECTION 
1 
2 
3 
4 
5 
1 
Mix / Monitor Meters 
The main meters follow the selected monitor source. 
The default display is the post master level, which is 
overridden with an input channel level if the channel cue 
switch is selected. 
In split cue mode, the left master meter will display the 
cued channel signal level and the right master meter will 
display the mix level. The cued mix audio is pre level to 
prevent mismatch due to the position of the master 
level control. 
The mixer should be operated with these meters aver-
aging around ‘0’ with loudest peaks no higher than ‘+6’. 
2 
Output Limit Active LED 
If the output limiter has been engaged this LED will illu-
minate to indicate that the threshold has been exceeded 
and the limiter is active. The limiter is POST the Master 
Level control. 
3 
Mix Master Level Control 
A rotary master control adjusts the level of the main 
mix XLR outputs feeding the house sound system. This 
does not affect the monitor output or the meter read-
ing. 
4 
Mix Mono Switch 
Sums the left and right signal levels to produce a mono 
mix from both outputs. 
5 
Monitor Master Level Control 
Adjusts the level of the signal to the stereo monitor 
RCA output. This does not affect the headphones. The 
monitor output could be used for a booth monitor, re-
cording or an additional zone feed. 