User manual
Publication ENET-UM001I-EN-P - January 2010 75
Configure a Supervisor on a Device-level Ring Network Chapter 5
Verify Supervisor
Configuration
You may want to verify that your supervisor configuration has taken place and
that the ring network is functioning properly. You can verify that configuration
and a normally functioning network in either RSLogix 5000 programming
software or RSLinx Classic software.
1. Access the module properties
as shown previously in this chapter.
2. Click the Network tab.
3. Check the Network Topology and Network Status fields.
T
hey should display Ring and Normal respectiv
ely, as shown below.
For a 1756-EN2TR module, you can also ve
rify the supervisor configuration
through the module’s diagnostic web pages. For more information on
monitoring diagnostics via an EtherNet/IP module’s web pages, see Monitor
Diagnostics on
page 137
.
Troubleshoot DLR
Network Issues
For a full description of how to troubleshoot DLR network issues, such as
replacing a node on a DLR network, see the EtherNet/IP Embedded Switch
Technology Application Guide, publication
ENET-AP005
.
Check these fields.