Specifications
Presence Sensing Safety Devices
Safety Light Curtains
2-77
Visit our website: www.ab.com/catalogs
Publication S117-CA001A-EN-P
Accessories
GeneralPrinciples
2-Opto-electronics
Safety SwitchesOperator
Interface
LogicPower
R
GuardShield Washdown Enclosures
Cat. No.
Use with Light
Curtain Cat. No.
AB1C
Protective Height
[mm (in.)]
Mounting Value
[mm (in.)]
Total Length
[mm (in.)]
440L-AGST320
440L-P4®0320YD
320 ±0.5 (12.6 ±0.02) 542.58 (21.36) 564.58 (22.23)
440L-AGST480
440L-P4®0480YD
480 ±0.5 (18.9 ±0.02) 702.58 (27.66) 724.58 (27.66)
440L-AGST640
440L-P4®0640YD
640 ±0.5 (25.2 ±0.02) 862.58 (33.96) 884.58 (34.83)
440L-AGST800
440L-P4®0800YD
800 ±0.5 (31.5 ±0.02) 1022.58 (40.26) 1044.58 (41.13)
440L-AGST960
440L-P4®0960YD
960 ±0.5 (37.8 ±0.02) 1182.58 (46.56) 1204.58 (47.42)
® Replace with J for 14 mm or K for 30 mm.
GuardShield PAC
Cat. No.
Use with Light
Curtain Cat. No.
AB1C
Protective Height
[mm (in.)]
Mounting Value
[mm (in.)]
Total Length
[mm (in).]
440L-AGST960
440L-P4A3400YD
810 ±0.5 (31.8 ±0.02) 1182.58 (46.56) 1204.58 (47.42)
440L-AGST640 440L-P4A2500YD 810 ±0.5 (31.8 ±0.02) 1182.58 (46.56) 884.58 (34.83)
The GuardShield washdown enclosure is designed to provide an environmentally protective enclosure for the GuardShield Type 4 and
GuardShield PAC safety light curtains when they are applied in washdown applications. There is a range loss of approximately 10% when
GuardShield light curtains are mounted inside of the IP67 washdown enclosures.
Approximate Dimensions
Dimensions are shown in mm (in.). Dimensions are not intended to be used for installation purposes.
151.6
(5.97)
130 (5.12)
102.6
(4.04)
111.5
(4.39)
82
(3.23)
93
(3.66)
62.2
(2.45)
A
Detection Zone
C
B1
4.0 (0.16)
(Mounting)
131.6
(5.18)
7.1 (0.28)
140.5