Specifications
Long scan range (up to 70 m (300 ft))
Easy installation
Die cast aluminium housing
Heated front lens, allowing use even in outdoor applications
Relay outputs
Safety Ratings
Standards IEC 61496, Parts 1 & 2
Safety Classification
Type 4, IEC 61496; SIL 3 (IEC 61508); SIL
CL3 (IEC 62061); Category 4 (EN ISO
13849); PLe (EN ISO 13849); B
10d
parameter: 1 x 10
6
switching cycles (@ DC-
13, 24V, 0.6 A); 2 x 10
5
switching cycles (@
DC-13, 24V, 1.5 A) PFH
d
: 4.0 x 10
-9
;
Mission time: 20 years
Certifications
CE Marked for all applicable directives and
BG
Power Supply
Input Power, Max. 24V DC ±20%
Maximum Residual Ripple
5% of U
v
, max.
Power Consumption 24V DC 8 W max.
Outputs
Safety Outputs 2 N.O. Relays
Switching Current @ Voltage,
Min.
0.02 A to 2 A
Operating Characteristics
Response Time < 22 ms
Status Indicators On state, Off state, alignment
Beam Diameter 23 mm (0.91 in.)
Scanning Range
0.5…20 m (1.64…65.5) or 15…70 m
(49.2…300 ft)
Synchronization Optical
Wavelength 950 nm
Environmental
Enclosure Type Rating IP67 (EN 60529)
Relative Humidity 15…95%, noncondensing
Operating Temperature [C (F)] -25…55° (-13…131°)
Vibration 5 g, 10…55 Hz per IEC 60068-2.6
Shock 10 g, 16 ms per IEC 60068-2.29
Physical Characteristics
Front Window Heated
Weight
Transmitter unit: approx. 0.9…1.3 kg
Receiver unit: approx. 1…1.4
Housing Cross Section 50 x 156 x 116 mm (1.96 x 6.14 x 4.56 in.)
Connection Type
Terminal chamber with cable gland (PG13.5
thread)
Cable Length 50 m (164 ft) max.
Note: The external power supply must be capable of buffering brief power
failures of 20 ms as specified in IEC 60204-1.
Robotic work cells
Processing machines
Machining centers
Palletizers
Transfer lines
High bay warehouses
The Area Access Control (AAC) safety single-beam is a 24V DC
through-beam opto-electronic safety switch offered with two
operating ranges (a short range (0.5…20 m (1.64…65.5 ft) or a long
range (15…70 m (49.2…300 ft)) system. The AAC system uses the
same transmitter for both ranges and one of two receivers for a
short-range or long-range system. This unique system configuration
minimizes the number of cat. nos. necessary for specifying the AAC
single-beam system.
The AAC safety single-beam is used as a whole-body detection
device. The light beam produced between the AAC transmitter and
receiver provides whole-body access detection for hazardous areas
such as: