Specifications
Presence Sensing Safety Devices
PAC Type 4 Safety Light Curtains
2-59
Visit our website: www.ab.com/catalogs
Publication S117-CA001A-EN-P
GuardShield PAC
GeneralPrinciples
2-Opto-electronics
Safety SwitchesOperator
Interface
LogicPower
R
Cordsets—Two Required (one for transmitter and one for receiver)
Female Connector (Sensor End) Cable
Wire Rating Length [m (ft)]
Cat. No.Face View of Female Connector Style Pin/Wire Color
Transmitter
4
3
1
2
Straight Female
1 Brown
2 White
3 Blue
4 Black
22 AWG
300V
4 A
2 (6.56)
889D-F4AC-2
5 (16.4)
889D-F4AC-5
10 (32.8)
889D-F4AC-10
15 (49.2)
889D-F4AC-15
20 (65.6)
889D-F4AC-20
30 (98.4)
889D-F4AC-30
Receiver
5
6
7
8
4
3
1
2
Straight Female
1 White
2 Brown
3 Green
4 Yellow
5 Grey
6 Pink
7 Blue
8 Red
24 AWG
30V AC/36V DC
1.5 A
2 (6.56)
889D-F8AB-2
5 (16.4)
889D-F8AB-5
10 (32.8)
889D-F8AB-10
15 (49.2)
889D-F8AB-15
20 (65.6)
889D-F8AB-20
30 (98.4)
889D-F8AB-30
Dimensions are not intended to be used for installation purposes.
47 (1.85)
14
(0.56)
Straight Female
Cordsets Approximate Dimensions [mm (in.)]
Muting Sensors
Sensor Type Connection Location Type Cat. No.
Retroreflective Connected directly to muting module
Dark Switching
42GRU-9000-QD
Transmitted Beam
Receiver (connected directly to the muting
module)
42GRR-9000-QD1
Retroreflective Connected directly to muting module
42GRU-9000-QD1
Polarized Retroreflective Three inch standard reflector 92-39
Polarized Retroreflective Connected directly to muting module
42GRU-9200-QD1
Polarized Retroreflective Three inch standard reflector 92-39
Mechanical Limit Switch
Connected directly to muting module
(operating lever must be selected
separately)
802M-NX101
Muting lamp Two cat. nos. make this assembly.
855E-24TL7
855E-BVMC
1Use with 4-pin, DC Micro cordset when connecting to muting module (5 m length shown). 1 m, 2 m, 3 m, and 5 m lengths
available.
889D-F4AC-5
Accessories