Specifications

Visit our website: www.ab.com/catalogs
Publication S117-CA001A-EN-P
Presence Sensing Safety Devices
POC Type 2 Safety Light Curtains
2-50
GuardShield Safe 2
General Principles
2-Opto-electronics
Safety Switches Operator
Interface
Logic Power
R
Description
Features
ATTENTION
Safety light curtains of a Type 2 level of
safety typically do not meet OSHA or ANSI
requirements of “Control Reliability,”
therefore it is not allowable to use a safety
device of a Type 2 level on or around
equipment or machinery that requires
“Control Reliability.”
Applications
M12 connectors
Optically synchronized
Integrated laser alignment system
IP65 enclosure rating
Simple Installation
cULus Listed and CE Marked for all applicable directives
Conveyors
Textile machinery
Automatic storage and retrieval machinery
Automated assembly lines
Specifications
Safety Ratings
Standards
IEC/EN61496 Parts 1 and 2, UL61496 Parts
1 and 2, UL1998
Safety Classification
Type 2 per IEC/EN61496. Category 2
device per EN 954-1, SIL 2 per IEC 61508,
PLd per EN/ISO 13849
Certifications
cULus Listed, TÜV, and CE Marked for all
applicable directives
Power Supply
Input Power, Max.
24V DC ± 20% (U
sp
)
Maximum Residual Ripple
< 10% of U
sp
Power Consumption <500 mA (no load)
Outputs
Safety Outputs 2 PNP OSSD. 0.3 A, short-circuit protected
Output Voltage, Min.
U
sp
-1
Switching Current @ Voltage,
Min.
300 mA @ 24V DC
Operating Characteristics
Response Time Varies by protective height
Indicator LEDs ON -State, OFF-State, internal error
Protected Height [mm (in.)]
120…1920 mm (4.7…75.6 in.) in 120 mm
(4.7 in.) increments
Resolution [mm (in.)] 30 mm (1.18 in.)
Scanning Range 0…18 m (0…59 ft)
Synchronization Optical, first beam adjacent to LEDs
Wavelength 950 nm
Environmental
Enclosure Type Rating IP65
Relative Humidity 15…95% (noncondensing)
Operating Temperature [C (F)] 0…55 ° (0…131 °)
Vibration
IEC 60068-2-6 frequency 10…55 Hz;
amplitude 0.35 mm (0.01 in.)
Shock
IEC 60068-2-29; acceleration 10 g, pulse
duration 16 ms 10…55 Hz; amplitude
0.35 mm (0.01 in.)
Physical Characteristics
Mounting
Rear mounting, standard and adjustable
(180°)
Weight Varies by protective height
Housing Cross Section 30 x 40 mm (1.18 x 1.57 in.)
Connection Type
Transmitter: 5-pin M12 micro QD
Receiver: 5-pin M12 micro QD
Cable Length 30 m (98.4 ft) max.
ILAS Laser Class Class 2, IEC 60825-1
The Allen-Bradley Guardmaster GuardShield Safe 2 safety light
curtain is a new addition to the Allen-Bradley Guardmaster portfolio
of opto-electronic safety devices. The “Type 2” designation means
that this particular safety light curtain meets a lesser requirement for
performance under fault conditions than the GuardShield Type 4
safety light curtains. As a result, the GuardShield Type 2 safety light
curtain can only be applied in applications where a formal risk
assessment has determined that a Type 2 device is sufficient to
meet the level of risk posed by the hazard.
The GuardShield Safe 2 safety light curtain is a self-contained two-
box, safety light curtain in a robust housing with an integrated laser
alignment system. The integrated laser alignment system generates
two visible beams of light which simplifies alignment of the light
curtain pair.
This economical opto-electronic Type 2 safety light curtain is offered
in a guard-only mode of operation and is designed for use on or
around machinery or equipment where a formal risk assessment has
determined that a Type 2 safety device is of a sufficient level of
safety to meet the guarding application.