Specifications
Allen-Bradley ControlLogix Ethernet Driver Help
N7:0 Word 0
N7/26 Bit 26
N12:4/15 Bit 15 word 4
N7:10 [8] 8 element array starting at word 10
N15:0 [4] [5] 4 by 5 element array starting at word 0
Float Files
To access float files, specify a file number and an element. The default data types are shown in bold.
Syntax Data Type Access
F<file>:<element> Float Read/Write
F<file>:<element> [rows][cols] Float (array type) Read/Write
F<file>:<element> [cols] Float (array type) Read/Write
The number of array elements (in bytes) cannot exceed the block request size specified. This means that array
size cannot exceed 8 floats given a block request size of 32 bytes.
Ranges
PLC Model File Number Max. Word
MicroLogix 8-999 999
SLC 500 Fixed I/O NA NA
SLC 500 Modular I/O 8-999 999
PLC-5 Series 3-999 1999
Examples
Example Description
F8:0 Float 0
F8:10 [16] 16 element array starting at word 10
F15:0 [4] [4] 16 element array starting at word 0
ASCII Files
To access ASCII file data, specify a file number and a character location. The default data types are shown in
bold.
Syntax Data Type Access
A<file>:<char> Char, Byte* Read/Write
A<file>:<char> [rows][cols] Char, Byte* Read/Write
A<file>:<char> [cols] Char, Byte* Read/Write
A<file>:<word offset>/length String** Read/Write
*The number of array elements cannot exceed the block request size specified. Internally, the PLC packs two
characters per word in the file, with the high byte containing the first character and the low byte containing the
second character. The PLC programming software allows access at the word level or two-character level. The
Allen-Bradley ControlLogix Ethernet Driver allows accessing to the character level.
Using the programming software, "A10:0 = AB," would result in 'A' being stored in the high byte of A10:0 and 'B'
being stored in the low byte. Using the Allen-Bradley ControlLogix Ethernet Driver, two assignments would be
made: "A10:0 = A" and "A10:1 = B." This would result in the same data being stored in the PLC memory.
**Referencing this file as string data allows access to data at word boundaries like the programming software.
The length can be up to 232 characters. If a string that is sent to the device is smaller in length than the length
specified by the address, the driver null terminates the string before sending it down to the controller.
Ranges
PLC Model File Number Max. Character
MicroLogix 3-255 511
SLC 500 Fixed I/O NA NA
SLC 500 Modular I/O 9-999 1999