Read request for <count> element(s) starting at <tag address> on device <device name> failed
due to a framing error. Block deactivated.
106
Unable to read <count> element(s) starting at <tag address> on device <device name>. Block
deactivated.
106
Unable to read <count> element(s) starting at <tag address> on device <device name>. [CIP
error=<code>, Ext. error=<code>].
106
Unable to read <count> element(s) starting at <address> on device <device>. Controller tag data
type <type> unknown. Block deactivated.
106
Unable to read <count> element(s) starting at <address> on device <device>. Data type <type>
is illegal for this block.
107
Unable to read <count> element(s) starting at <address> on device <device>. Data type <type>
not supported.
107
Unable to read <count> element(s) starting at <tag address> on device <device name>. Block
does not support multi-element arrays. Block deactivated.
107
Write Errors
107
Unable to write to <tag address> on device <device name>.
108
Unable to write to tag <tag address> on device <device name>. [CIP error=<code>, Ext.
Status=<code>].
108
Unable to write to tag <tag address> on device <device name>. Controller tag data type <type>
unknown.
108
Unable to write to tag <tag address> on device <device name>. Data type <type> is illegal for this
tag.
109
Unable to write to tag <tag address> on device <device name>. Data type <type> not supported.
109
Unable to write to tag <tag address> on device <device name>. Tag does not support multi-
element arrays.
109
Write request for tag <tag address> on device <device name> failed due to a framing error.
109
Project Synchronization Errors
110
Encapsulation error occurred while uploading project information. [Encap. error=<code>].
110
Error occurred while uploading project information. [CIP error=<code>, Ext. error=<code>].
110
Framing error occurred while uploading project information.
110
Invalid or corrupt controller project detected while synchronizing. Synchronization will be retried
shortly.
111
Low memory resources.
111
Project download detected while synchronizing. Synchronization will be retried shortly.
111
Unable to read <element> element(s) starting at <address> on device <device name>. Native tag
size mismatch.
112
Unable to read tag <tag name> on device <device name>. Native tag size mismatch.
112
Unable to write to tag <tag name> on device <device name>. Native tag size mismatch.
112
ENI/DH+/ControlNet Gateway Specific Error Messages
112
Device <device name> is not responding. Local node responded with error [DF1 STS=<value>].
112
Unable to read <block size> element(s) starting at <address> on device <device name>. [DF1
STS=<value>, EXT STS=<value>]. Tag(s) deactivated.
113
Unable to read <block size> element(s) starting at <address> on device <device name>. Frame
received contains errors.
113
Unable to write to address <address> on device <device name>. [DF1 STS=<value>, EXT
STS=<value>].
113
Unable to write to address <address> on device <device name>. Frame received contains errors.
114
Unable to write to address <address> on device <device name>. Local node responded with error
[DF1 STS=<value>].
114
Unable to write to function file <address> on device <device name>. Local node responded with
error [DF1 STS=<value>].
114
Automatic Tag Database Generation Errors
115
www. kepware.com
5