Specifications
Allen-Bradley ControlLogix Ethernet Driver Help
1 Port ID Port to backplane. Decimal 1
Optional
Routing Path
Multiple Link,
port pairs
Specifies a way out of the Ethernet/IP interface module
and must equal 1 (port to the backplane).
Decimal *
CPUSlot Link Address Slot number of the CPU module that contains the serial
port used for communications.
Decimal 0-255
Serial Port
Channel
Serial port channel to use. Alpha A and
B
Station ID DF1 station ID of target PLC in Decimal Format.** Decimal 0-255
*For more information, refer to Connection Path Specification.
Example
123.123.123.123,1,0.A.3
This equates to an Ethernet/IP of 123.123.123.123. The CPU card resides in slot 0: use Channel A (serial port)
and addressing target station ID 3 (dec).
Note 1: For information on supplementing a Device ID with a routing path to a remote serial node, refer to
Communications Routing.
Note 2: For more information on communications parameters, refer to Logix Communications Parameters.
Note 3: When configuring the Device ID, users should verify that the device can be detected using the same
route through RSLinx.
MicroLogix 1100 Setup
MicroLogix 1100 Device ID
The Device ID specifies the IP address of the MicroLogix 1100. Device IDs are specified as the following:
<IP or hostname>
Designator Designator Type Description Formats Range
IP/Host Name N/A IP Address or host name. Decimal 0-255
Example
123.123.123.123
This equates to an IP of 123.123.123.123.
Note: For more information on communications parameters, refer to ENI DF1/DH+/ControlNet Gateway
Communications Parameters.