Specifications

Allen-Bradley ControlLogix Ethernet Driver Help
2 or more Ethernet/IP Interface modules (such as 1756-ENBT).
MicroLogix, SLC500, or PLC-5 series PLC with Ethernet/IPconnectivity.
Note: EthernetIP Gateway models do not support automatic tag database generation.
Ethernet/IP Gateway Device ID
The device ID specifies the local device IP address as well as the remote Ethernet/IP address necessary for
making a connection. Device IDs are specified as the following:
<IP or hostname>,1,[<optional routing path>],<ENBT Slot>.<ENBT Channel>.<Remote IP>
Designator
Designator
Type*
Description Formats Range
IP/Host Name N/A IP Address or host name of the local Ethernet/IP
interface module.
Decimal 0-255
1 Port ID Port to backplane. Decimal 1
Optional
Routing Path
Multiple Link,
port pairs
Specifies a way out of the Ethernet/IP interface module
and must equal 1 (port to the backplane).
Decimal *
ENBTSlot Link Address The slot number of the second Ethernet/IP interface
module.
Decimal 0-255
ENBTChannel Port ID The Ethernet/IP port to use. Alpha A and
B
Remote
IPAddress
Link Address The remote IPaddress of the target PLC. Decimal 0-255
*For more information, refer to Connection Path Specification.
Example
123.123.123.123,1,2.A.192.168.1.10
This equates to a local IP of 123.123.123.123. The second Ethernet/IP card resides in slot 2: use port A and
addressing target device with IP 192.168.1.10.
Note 1: For information on supplementing a device ID with a routing path to a remote Ethernet/IP device, refer to
Communications Routing.
Note 2: For more information on communications parameters, refer to ENI DF1/DH+/ControlNet Gateway
Communications Parameters.
Note 3: When configuring the device ID, users should verify that the device can be detected using the same
route through RSLinx.
Serial Gateway Setup
Serial Gateway provides a means of communicating with ControlLogix, CompactLogix, FlexLogix, and SoftLogix
PLCs on a serial network with the Allen-Bradley ControlLogix Ethernet Driver.
Requirements
Ethernet/IP Interface module.
Local CPU with a serial port.
Remote ControlLogix, CompactLogix, FlexLogix, or SoftLogix CPU with a serial port.
Note 1: Local and Remote CPUs must be on the same serial network.
Note 2: Serial Gateway models do not support automatic tag database generation.
Serial Gateway Device ID
The device ID specifies the local device IP address as well as the remote device station ID necessary for making a
connection. Device IDs are specified as the following:
<IP or hostname>,1,[<Optional Routing Path>],<CPU Slot>.<Serial Port Channel>.<Station ID (dec)>
Designator
Designator
Type*
Description Formats Range
IP/Host Name N/A IP address or host name. Decimal 0-255