User manual
Overview 1–4
LED Indicators
Seven LEDs provide the following indications.
Indicator Condition Indicates:
Green Normal operating state
Flashing Green Initialization and/or incorrect (unconfigured)
configuration
Module
Red
Processor fault (nonrecoverable)
Mo
d
ul
e
Flashing Red Minor fault (recoverable). Occurs when down-
loading firmware.
Off No power applied to Reader
Green Normal DeviceNet operating state
Flashing Green Communication link established, but not data
transfer.
Netw r
Red Communication fault
Network
Flashing Red
One or more DeviceNet devices are not re-
sponding. Reader may not be able to perform
all configured functions.
Off DeviceNet communications not established
La er
Yellow Scan beam on
La
s
er
On
Off
Scan beam off
Yellow Scanning and decoding bar code symbol
On Symbol
Flashing
Bar code symbol read at less than 100% rate
On S
ym
bol
Off
Not scanning bar code symbol
Yellow Package detected
Trigger / Read
Green
Valid read
Tr
i
gger
/
Read
Off No trigger or no valid bar code symbol read
I/ 1
Yellow Input/Output module 1 active
I/
O
1
Off Input/Output module 1 not active
I/ 2
Yellow Input/Output module 2 active
I/
O
2
Off Input/Output module 2 not active
Wiring Base Connector
The 24-pin connector on the bottom of the Reader plugs into the
socket on the wiring base. No other connections to the Reader are
required.
Operating Environment
The Reader operates under a variety of conditions.
• Cast aluminum enclosure meets NEMA Type 4 requirements
when used with the wiring base.
• Operates in environments from 32 to 122F (0 to 50C).
• Mounts at any angle.
See Appendix A for a complete list of Reader specifications.