User manual

Communication Setup (Cable Configuration)4-24
Publication 2755-6.2
AdaptaScan Pass Through Cable Options
The following define the communication options available when the
scanner is connected to the AdaptaScan pass through cable.
Catalog No. 2755-HDC-GA2-08
Default Settings
Scan the SET ADAPTASCAN PASS THROUGH CABLE DEFAULTS
bar code to set the default settings. The table below lists the defaults.
Item Default Setting
Refer to
Description
on Page:
Programming
Guide
Page Reference
Baud Rate 9600 4-25 2-26
Parity
Even
4-25 2-27
Stop Bits
2
4-26 2-28
Data Bits
7
4-26 2-28
Hardware Handshaking None 4-27 2-29
Software Handshaking None 4-28 2-30
Beep on BEL Disabled 4-29 2-31
Intercharacter Delay 0 4-26 2-32
Bar Code Programming Guide for Decoded Scanners (Publication 2755-6.5).
We recommend that you set Parity = None, Stop Bits = 1, and Data Bits = 8 for
communication with the AdaptaScan Bar Code Reader.