User manual
Connecting and Operating Scanner 2-11
Publication 2755-6.2
The custom cable for the AdaptaScan Pass Through cable connects to the
RS-232 and package detect terminals in the AdaptaScan wiring base.
Transmit (Tx)
No Connection
Receive (Rx)
Clear to Send (CTS)
Ready to Send (RTS)
Shield (SHD)
Custom Cable
Maximum length of
18 inches (.46 meter)
AdaptaScan Wiring Base
PKG DET
+12VDC
Ground
25-Pin
Female DB Connector
No Connection
No Connection
The following table provides the pinout connections for the cable (DB
25-pin female connector).
Pass Through Cable
Pin Number
(DB25 Connector)
Function AdaptaScan Terminal Connection
2 Receive Data Input Tx (RS-232 Terminal Block)
3 Transmit Data Output Rx (RS-232 Terminal Block)
4 CTS Input RTS (RS–232 Terminal Block)
5 RTS Output CTS (RS-232 Terminal Block)
7 Ground GND (Package Detect Terminal Block)
9 +V 4.8 to 14.0V DC 12V (Package Detect Terminal Block)
Shield Shield Ground SHD (RS-232 Terminal Block)