5–20 Communication Setup (Synapse Cable)
Publication 2755-6.4
Setting Scanner Emulation Synapse Cable Options (Continued)
Emulation
Select the type of emulation your decoder requires.
The selections are:
• Standard Emulation (default)
• MSI Wand Emulation
• Texlon Wand Emulation
• Norand Wand Emulation
Variable Leading Margin
Sets the leading margin for wand emulation. The leading margin can
be varied to allow more time for the decoder to wake up before the
bar code data is received. The selections are:
• 80 msec (default)
• 140 msec
• 200 msec
Check for Decode LED
When enabled (default), a transmission error occurs if the decode
LED line from the host is not active.