2–14 Connecting the Scanner
Publication 2755-6.4
Scanner to SLC Connection
Use the 9-Pin RS-232 Synapse cable (Catalog No.
2755-HFC-SR3-01) to connect the scanner cable to the Channel 0
port on an SLC-5/03 or 5/04. The Channel 0 port must be
configured for RS-232 communications.
SLC 5/04
Channel 0
To Channel 0 Port
Power Supply
Scanner Cable
RS-232 Synapse Cable
(2755-HFC-SR3-01)
Scanner
Note: Connect the
power supply last.
Refer to the user manuals for the Allen-Bradley Advanced
Programming Software (APS) to make sure the Channel 0 settings
match the Synapse cable settings.