Specifications

FLEX I/O Remote I/O Adapter4
Publication
1794-5.46 – November 1998
!
ATTENTION: Make certain that the flexbus
connector is completely clear of the adapter. The slide
must be completely to the right and the raised spot on the
slide visible.
5. Release the locking tab and remove the adapter.
6. Before installing the new adapter, notice the notch on the right rear of
the adapter. This notch accepts the hook on the terminal base unit. The
notch is open at the bottom. The hook and adjacent connection point
keep the terminal base and adapter tight together, reducing the
possibility of a break in communication over the backplane.
!
ATTENTION: Make certain that the hook on the
terminal base is properly hooked into the adapter. Failure
to lock the hook into the adjacent base/adapter can result
in loss of communication on the backplane.
7. Complete the adapter mounting as shown below.
20127
C
Push down and in at the
same time to lock the
adapter to the DIN rail.
When the adapter is locked onto the DIN rail,
gently push the flexbus connector into the
adapter to complete the backplane.