User manual

Publication 1794-UM063A-EN-P - March 2006
2-16 Configurable FLEX I/O Analog Module Features
Analog Output Module (1794-OE8H) Image Table Mapping
Table 2.13 Input Map (Read Words)
Bit
15 14 13 12 11 10 09 08 07 06 05 04 03 02 01 00
Word
0Flt
Alm
ch7
Flt
Alm
ch6
Flt
Alm
ch5
Flt
Alm
ch4
Flt
Alm
ch3
Flt
Alm
ch2
Flt
Alm
ch1
Flt
Alm
ch0
Reserved Diagnostic Status
1 Reserved
2H
Rb
ch 7
H
Rb
ch 6
H
Rb
ch 5
H
Rb
ch 4
H
Rb
ch 3
H
Rb
ch 2
H
Rb
ch 1
H
Rb
ch 0
H
Fail
ch 7
H
Fail
ch 6
H
Fail
ch 5
H
Fail
ch 4
H
Fail
ch 3
H
Fail
ch 2
H
Fail
ch 1
H
Fail
ch 0
3H
Tmt
ch 7
H
Tmt
ch 6
H
Tmt
ch 5
H
Tmt
ch 4
H
Tmt
ch 3
H
Tmt
ch 2
H
Tmt
ch 1
H
Tmt
ch 0
H
Cm
ch 7
H
Cm
ch 6
H
Cm
ch 5
H
Cm
ch 4
H
Cm
ch 3
H
Cm
ch 2
H
Cm
ch 1
H
Cm
ch 0
Where: ch = channel
Flt Alm = Fault Alarm
H Rbd = HART Rebuild
H RB = HART Readback
H Fail = HART Failure
H Tmt = HART Transmitter
H Cm = HART Communication
Table 2.14 Output Map (Write Words)
Bit
15 14 13 12 11 10 09 08 07 06 05 04 03 02 01 00
Word
0 Reserved Glbl
Rst
Reserved Dig
Out
ch 7
Dig
Out
ch 6
Dig
Out
ch 5
Dig
Out
ch 4
Dig
Out
ch 3
Dig
Out
ch 2
Dig
Out
ch 1
Dig
Out
ch 0
1 Channel 0 Output Data
2 Channel 1 Output Data
3 Channel 2 Output Data
4 Channel 3 Output Data
5 Channel 4 Output Data
6 Channel 5 Output Data
7 Channel 6 Output Data
8 Channel 7 Output Data
Where: ch = channel
Dig Out = Digital Output
Glbl Rst = Global Reset