User manual
Publication 1794-UM063A-EN-P - March 2006
C-14 Additional HART Protocol Information
68 Trim analog output
gain
0 Analog output number
code
— — As in command —
1 Analog output units
code
2…5 Externally measured
analog output level
(F)
69 Write analog output
transfer function
0 Analog output number
code
— — As in command —
1 Analog output transfer
function code
70 Read analog output
end point values
0 Analog output number
code
— 0 Analog output number
code
—
1 Analog output end
point units code
2…5 Analog output upper
end point value
6…9 Analog output lower
end point value
107 Write burst mode
transmitter variables
(for Command #33)
0 Transmitter variable
code for slot 0
— — As in command —
1 Transmitter variable
code for slot 1
2 Transmitter variable
code for slot 2
3 Transmitter variable
code for slot 3
108 Write burst mode
command number
0 Burst mode command
number
— — As in command —
109 Burst mode control 0 Burst mode control
code (0 = exit, 1 =
enter)
— — As in command —
Table C.6 Common Practice Commands
Command Data in Command Data in Reply
# Function Byte Data
Type
(5)
Byte Data
Typ e