Technical data
A-B SuperBridge Technical Reference
28
State Meaning
2 Normal LIW feed
3 Filling
4 Stabilization time after filling
5 Run cleanout cycle to low weight
6 Run Cleanout cycle (time) after low
State Meaning
weight
7 Feeder Stopped
8 A Blocking condition occurred
31.51.EX
State Meaning
0 Waiting for next Batch
1 Preparing for a batch
2 Wait to become stable
3 Zero scale
4 Fill bucket
5 Wait to become stable and check
weight
6 Open batch gate
State Meaning
7 Wait to empty
8 Close Batch Gate
9 Aborted Batch
10 A Blocking Condition occured
11 A Fault Occurred
12 Restart batching
35.00.EX
State Meaning
0 Test for autofill
1 Stopped by button 7, "STOP
BATCH"
2 ready for start of new batch,waiting
for "START BATCH" or LOIN)
3 Batchout starts here
4 Prep for mandatory wait before
stable, before batching
5 Wait before stable, before batching
6 Stable check before batching
7 Check if coase feeding or skip to
finefeed
8 Start coarse feed
9 Coarse feeding, check for empty,
coarse done, pause, net increasing
10 Check if skip fine feed, anr set dirty
= NO
11 Start fine feed
12 Fine feeding, check for empty, fine
done, pause, increasing net
State Meaning
13 Arm timer for mandatory wait
14 Wait before stable after batching
15 Wait for stable after batching
16 Calc weight batched out so far
17 Calculate new preact
18 Prepare for filling
19 Arm timer before filling
20 Wait before fill
21 Wait for stability for filling
22 start filling
23 Filling, check for overfill, done
24 Stop filling
25 Initialize for Cleanout
26 Run cleanout
27 Run cleanout for empty time
28 hopper weight past empty weight
29 check for rerun or return