Technical data
A-B SuperBridge Technical Reference
27
Note that the status of unused digital inputs in MCs are reported to the MC Digital I/O,
N12:2,10,18.. (page 15), even if they are not used by he MC application. They can be used as
remote inputs for the ladder logic.
INTERNAL STATE
Some cyclic controller applications have an internal state variable, useful for indication of what’s
going on in. The state variable is numerical, and can not be used for bit monitoring.
30.00.HP
State Meaning
0 Check for fill requirement at startup
1 Prepare for normal feed
2 Wait for filter values to stabilize
3 Norma LIW feed
4 Prepare for a fill cycle
5 Filling
6 Ceck for auto-fill condition
7 Preparations after fill cycle
State Meaning
8 Stabilization time after filling
9 Prepare for normal feed after filling
10 Prepare for cleanout cycle
11 Run cleanout cycle to low weight
12 Run Cleanout cycle (time) after low
weight
12 Waiting for fill after cleanout complete
35.00.HP
State Meaning
0 Test for autofill
1 Stopped by button 7, "STOP BATCH"
2 Ready for start of new batch
3 Preparing for a batch
4 Prepare for mandatory wait before
stable
5 Wait before stable, before batching
6 Stable check before batching
7 Check if fast feed needed
8 Start fast feed
9 Fast feeding
10 Check if skip fine feed
11 Start fine feed
12 Fine feeding
13 Init wait after feed
State Meaning
14 Wait before stable after batching
15 Wait for stable after batching
16 Calc weight batched out so far
17 Calculate new preact
18 Prepare for filling
19 Arm timer before filling
20 Wait before fill
21 Wait for stability for filling
22 Start filling
23 Filling, check for overfill, done
24 Stop filling
30.00.EX
State Meaning
0 Prepare for normal feed
State Meaning
1 Wait for filter values to stabilize