MODEL SPECIFIC INFORMATION
SuperBridge was released years after the MC² weighing controller. For some older versions of
the controller software applications, full support is not available. This chapter explains limitations
and application specific information that relates to specific MC² models.
SUPPORTED FUNCTIONS
The following table lists any limitations of SuperBridge operation in relation to different MC²
models and versions. Models not listed here are not supported at all.
MC² Models
External
I/O
Set
Points
Pacing Req.
Reg
Update
register
Max
Baud
Notes
20.00.K No One Yes Yes Yes 9600
22.00.B No One Yes Yes Yes 19200
30.00.D No One Yes Yes Yes 9600 Note 1
10.00.HP.O,A,B No No No No No 9600 Note 2
10.00.HP.C, D No Note 3 No Yes Yes 19200
11.00.HP.A No Note 3 No Yes Yes 19200
20.00.HP.O,A,B No Note 4 Yes Note 5 Note 5 9600 Note 2
20.00.HP.C No One Yes Yes Yes 19200
30.00.HP.O,A-D No One Yes Yes Yes 19200
35.00.HP.O,A No One Yes Yes Yes 19200
MC³ Models
20.00.EX.Beta O,A Yes One Yes Yes Yes 19200
20.10.O,A-F Yes One Yes Yes Yes 19200
20.20.EX.O,A Yes Two Yes Yes Yes 19200
24.10.EX.Beta Yes One Yes Yes Yes 19200
24.10.EX.O,A-I Yes One Yes Yes Yes 19200
24.96.EX.O,A No One Yes Yes Yes 19200
24.96.EX.B-C Yes One Yes Yes Yes 19200
24.95.EX.D-G Yes Two Yes Yes Yes 19200
30.00.EX.O-E Yes One Yes Yes Yes 19200
30.10.EX.Beta Yes One Yes Yes Yes 19200
30.10.X.O-E Yes One Yes Yes Yes 19200
30.20.EX.Beta Yes Two Yes Yes Yes 19200
31.51.EX.Beta Yes Note 3 Yes Yes Yes 19200
35.00.EX.O,A-B Yes Note 3 Yes Yes Yes 19200
40.10.EX.O,A Yes One Yes Yes Yes 19200 Note 2
Note 1: An error in the 30.00.D application makes it impossible for SuperBridge to detect
the fact that the scale is rerated, calibrated or altered in the diagnostics menu.
Note 2: This application should be updated to the latest version when used with
SuperBridge.