Solution:
Refer to the specific error's solution.
See Also:
Failed to perform M16 Diagnostic for base address '<memory address>'
Failed to perform M16 Key write for device '<device name>'
Failed to complete loading protocol file while performing M16 diagnosis for device '<device name>'
Failed to complete loading protocol while performing M16 diagnosis for device
<device name>
Error Type:
Fatal
Possible Cause:
One or more binary files related to M16 Diagnosis that came with the driver may have been corrupted.
Solution:
Contact Technical Support.
Failed to load binary resource <Resource ID> for device <Device>
Error Type:
Fatal
Possible Cause:
One of the binary files required for loading the protocol may be corrupted.
Solution:
Contact Technical Support.
Failed to allocate device for board '<channel>'
Error Type:
Fatal
Possible Cause:
1. The interface card is being used by another application.
2. The interface card is not functional.
3. If it is an ISA interface card, the memory address selected may be inappropriate.
Solution:
1. Uninstall any other application (such as RSLinx) that might be using the same interface card.
2. Verify that the card is functional and inserted properly in the appropriate slot.
3. Assign the correct memory address.
Error performing diagnostics test on channel '<channel name>'
Error Type:
Fatal
Possible Cause:
1. The card is not installed properly.
2. The card is corrupted.
Solution:
1. Verify that all the pins are hooked into the slot comfortably.
2. Replace the card.
SST Specific Error Messages
The following error/warning messages may be generated. Click on the link for a description of the message.
SST Specific Error Messages
Duplicate Station ID detected by device '<device name>'
Invalid Station ID detected by device '<device name>'