Installation Instructions ArmorPoint AC Input Modules, Series A (Cat. No. 1738-IA2M12AC3 and -IA2M12AC4) The ArmorPoint I/O family (Cat. no. 1738) consists of modular I/O modules. The sealed IP67 housing of these modules requires no enclosure. (Note that environmental requirements other than IP67 may require an additional appropriate housing.) I/O connectors are sealed M12 AC keyed (micro) styles. The mounting base ships with the module. The 1738-IA2M12AC3 and 1738-IA2M12AC4 modules are shown below.
ArmorPoint AC Input Modules, Series A Important User Information Solid state equipment has operational characteristics differing from those of electromechanical equipment. Safety Guidelines for the Application, Installation and Maintenance of Solid State Controls (Publication SGI-1.1 available from your local Rockwell Automation sales office or online at http://www.ab.com/manuals/gi) describes some important differences between solid state equipment and hard-wired electromechanical devices.
ArmorPoint AC Input Modules, Series A ATTENTION 3 Environment and Enclosure This equipment is intended for use in overvoltage Category II applications (as defined in IEC publication 60664-1), at altitudes up to 2000 meters without derating. This equipment is considered Group 1, Class A industrial equipment according to IEC/CISPR Publication 11.
ArmorPoint AC Input Modules, Series A ATTENTION Preventing Electrostatic Discharge This equipment is sensitive to electrostatic discharge, which can cause internal damage and affect normal operation. Follow these guidelines when you handle this equipment: • Touch a grounded object to discharge potential static. • Wear an approved grounding wriststrap. • Do not touch connectors or pins on component boards. • Do not touch circuit components inside the equipment.
ArmorPoint AC Input Modules, Series A 5 Install the mounting base as follows: 1. Lay out the required points as shown above in the drilling dimension drawing. 2. Drill the necessary holes for #8 (M4) machine or self-tapping screws. 3. Mount the base using #8 (M4) screws. 4. Ground the system using the ground lug connection. (The ground lug connection is also a mounting hole.
ArmorPoint AC Input Modules, Series A Install the ArmorPoint AC Input Module To install the ArmorPoint AC input module, proceed as follows. 1. Using a bladed screwdriver, rotate the keyswitch on the mounting base clockwise until the number 8 aligns with the notch in the base. 2. Position the module vertically above the mounting base. The module will bridge two bases. Module will bridge two bases. 1738-IA2M12AC3/A In 12V ac 0 1 MOD NET 0 1 43777 3.
ArmorPoint AC Input Modules, Series A Wire the AC Input Modules 7 Following are wiring instructions for the ArmorPoint AC input modules.
ArmorPoint AC Input Modules, Series A Communicate With Your Module I/O messages are sent to (consumed) and received from (produced) the ArmorPoint I/O modules. These messages are mapped into the processor’s memory. These ArmorPoint I/O input modules produce 1 byte of input data (scanner Rx - status). They do not consume I/O data (scanner Tx).
ArmorPoint AC Input Modules, Series A Troubleshoot With the Indicators 9 1738-IA2M12AC3 1738-IA2M12AC3/A In 12V ac 0 Module Status Indicators Network Status Indicators 1 MOD NET 0 I/O Status Indicators 1 43689 Indication Probable Cause Module Status Off No power applied to device Green Device operating normally Flashing Green Device needs commissioning due to missing, incomplete, or incorrect configuration Flashing Red Recoverable fault Red Unrecoverable fault - may require device repl
ArmorPoint AC Input Modules, Series A Indication Probable Cause I/O Status Specifications ArmorPoint AC Input Modules Inputs per Module On-state Voltage Maximum Minimum Nominal Off-state Voltage, Maximum On-state Current Minimum Nominal Off-state Current, Maximum Nominal Input Impedance Delay Time1 OFF to ON ON to OFF Keyswitch Position General Specifications LED Indicators PointBus Current, Maximum Power Dissipation, Maximum Thermal Dissipation, Maximum Isolation Voltage (continuous-voltage withst
ArmorPoint AC Input Modules, Series A General Specifications (continued) Shock Vibration ESD Immunity Radiated RF Immunity EFT/B Immunity Surge Transient Immunity Conducted RF Immunity Emissions Enclosure Type Rating Mounting Base Screw Torque Wiring Category2 Weight Imperial (Metric) Certifications: (when product is marked) 11 IEC60068-2-27 (Test Ea, Unpackaged Shock): Operating 30g Non-operating 50g IEC60068-2-6 (Test Fc, Operating): 5g @ 10-500Hz IEC 61000-4-2: 6kV contact discharges 8kV air discha
Rockwell Automation Support Rockwell Automation provides technical information on the web to assist you in using our products. At http://support.rockwellautomation.com, you can find technical manuals, a knowledge base of FAQs, technical and application notes, sample code and links to software service packs, and a MySupport feature that you can customize to make the best use of these tools.