Specifications
Page
4-6
1770-805
TABLE
4-1 -
Remote
Cable
Parts
PART
MANUFACTURER'S
DESTINATION
25-Pin Female
Connector
Cannon
Type
DB-25S,
or
equivalent
25-Pin
Male
Connector
Cannon
Type
DB-25P,
or
equivalent
Plastic
Hood
AMP
Type
205718-1
2
twisted
pair
22
guage,
Cat. No. 1778-CR
individually
shielded
cable
Belden 8723,
or
equivalent
Cannon
Amp,
Inc.
Belden
Corp.
666
E.
Dyer
P.O.
Box
3608
P.O.
Box
1327
Santa
Ana,
Harrisburg,
Richmond,
CA
92702
PA 17105
IN
47374
Channel
B
Protective
~
Ground
1
Transmitted--
2
Data
Pins
Received
Data
I
Return
Data
18
Terminal
20
/Ready
Transmitted
25~Data
Return
10063
FIGURE
4-9
-
Pinout
of
Channel
B
4.5.1
Connecting
RS-232-C Devices
to
Chan-
nelS
Modems,
computers,
or
other
non-Allen-
Bradley
RS-232-C devices can be
connected
to
Channel
B
using
one
of
two
cables. These
cables are
three
feet
long
and
differ
only
by
the
type
of
connectors.
They
are:
•
Industrial
Terminal/Data
Handling
Adapter
Cable
(Cat. No. 1770-CB) - has
two
male
connectors
•
Industrial
Terminal
Adapter
Cable
(Cat. No.
1770-CC) - has
one
male and
one
female
connector
Cable
can be
constructed
for
distances
up
to
50 feet.
The
pinout
of
Channel
B (Figure 4-9)
identifies
the
pins used.
The
cable
to
be used
is Cat. No. 1778-CR,
Belden 8723
or
its
equiva-
lent
and is
constructed
as
shown
in Figure
4-10.
The
parts
for
constructing
this
cable are
listed in
Table
4-1.
Note
that
pins
7,
18,
and
25
on
the
Industrial
Terminal
CRT
Monitor
end
of
the
cable
must
be
wired
together.
For RS-232-C
applications
that
require
dis-
tances
greater
than
50 feet, refer
to
the
EIA
RS-232-C
Standards
publication
for
guide-
lines.
4.5.2
Connecting
a
PLC
Processor
for
Report
Generation
The
Industrial
Terminal
System, in
Alpha-
numeric
mode, can be used
for
report
genera-
tion
with
a PLC Processor.
The
Industrial
Terminal
System can be
connected
locally
(13
cable-feet)
or
up
to
5000
cable
feet
from
the
PLC Processor.
The
local
configuration
(Figure
4-11)
shows
a
Series B
or
later
Data
Handling
Module
(Cat.
No. 1774-DH2) in
the
PLC
Processor
Chassis.
The ten
foot
Data
Handling
Interconnect
Cable
(Cat. No. 1774-DC2)
connects
this
Module
to
one
end
of
the
1770-CB
Cable.
The
other
end
of
the
1770-CB
Cable
connects
to
Channel
B.
The
5000
cable-foot
configuration
(Figure
4-
12) uses
the
same Data
Handling
Module
and
cable, and a
section
of
constructed
cable
(Cat.
No. 1778-CR,
Belden
8723
or
equivalent).
The