User manual
Publication 1394-5.0 — May 2000
3-22 Wiring System, Axis, and Shunt Modules, and Motors (for all systems)
Important: To improve the bond between the motor cable shield 
and the axis module PE ground, a cable shield clamp 
is included with the Series C axis modules.
Figure 3.14
Series C Axis Module Cable Clamp
2. Prepare one end of the motor cable for attachment to the cable 
shield clamp by removing the outer insulation and braided shield 
from the motor cable. Ensure approximately 51 mm (2.0 in.) of 
the insulated cable wires are exposed (refer to Figure 3.14).
3. Remove another 22 mm (.875 in.) of insulation to expose the 
braided shield underneath for clamp attachment.
Important: When cutting into the insulation use care not to cut 
into the braided shield underneath.
4. Position the cable shield clamp over the exposed braided shield 
(ensure clamp screw is behind clamp and not braided shield).
5. Tighten the clamp screw.
Important: Do not overtighten the clamp screw or damage to 
the braided shield may result.
6. Thread the bracket screw into the bottom of the axis module and 
tighten.
7. Connect an axis module connector kit (catalog number 1394-199) 
to each motor cable that you will use. Refer to instructions that 
come with the kit for the specific connections.
1394 front view
System module
ground bar
Feedback
cable clamps
Cable Preparation
Clamp Attachment
Wiring to Axis Module
Cable wires
Braided
shield
exposed
Cable
shield
clamp
Motor
cable
Clamp
screw
Bracket
screw
Axis
cable clamp
51 mm
(2.0 in.)
1
22 mm
(.875 in.)
1
Dimensions given are approximate and will vary 
depending on the specific installation. Keep wires 
as short as possible while maintaining adequate 
stress relief.
1