8-4 Configuring Your 1394 Analog Servo System
[100% Torq Vel]
Motor velocity at 100% rated motor torque.
Note: Before making modifications to Mtr Data 
parameters, [Motor Type] must be set to "custom 
motor".
Parameter Numbers 392
Parameter Group Mtr Data
Display Units rpm
Parameter Type Read/Write
Change While Running Ye s
Linkable No
Minimum Value 1 rpm
Maximum Value 8000 rpm
Default Value This is determined by the motor catalog number.
[300%Torq Vel]
Motor velocity at 300% rated motor torque.
Note: Before making modifications to Mtr Data 
parameters, [Motor Type] must be set to "custom 
motor".
Parameter Numbers 388
Parameter Group Mtr Data
Display Units rpm
Parameter Type Read/Write
Change While Running Ye s  
Linkable No
Minimum Value 1 rpm
Maximum Value 8000 rpm
Default Value This is determined by the motor catalog number.
[Anlg Vel Ofst]
An offset value that can be used on an analog 
velocity input to counter voltage offsets on that 
input. This value is added after the input scaling 
has taken place, therefore changing the analog 
input scaling will change this offset 
compensation.
Parameter Numbers 276, 277, 278, 279
Parameter Group Vel Cmd Data
Display Units rpm
Parameter Type Read/Write
Change While Running Ye s
Linkable No
Minimum Value- 496.00 rpm
Maximum Value+ 496.00 rpm
Default Value 0.00 rpm
[Anlg Vel Scal]
Use this parameter to determine how the A/D 
converter value is scaled. It is set to the number 
of motor rpm that is to represent 1 volt of input 
command. The desired input velocity command 
voltage to motor rpm scaling is accomplished 
with this parameter. The default setting is 500 
rpm/volt. Use the following formula if the 
maximum motor speed (rpm) and maximum 
velocity command (volts) are known.
Parameter Numbers 272, 273, 274, 275
Parameter Group Vel Cmd Data
Display Units rpm/v 
Parameter Type Read/Write
Change While Running Ye s
Linkable No
Minimum Value- 1000.0 rpm/v
Maximum Value +1000.0rpm/v
Default Value +500.0 rpm/v 
for example:
[ATune Current]
The motor current used while an auto tune cycle 
is executing is specified with this parameter. In 
most cases, the default setting will be 
satisfactory.
Parameter Numbers 288, 289, 290, 291
Parameter Group ATune Config
Display Units amps
Parameter Type Read/Write
Change While Running Ye s
Linkable No
Minimum Value 10% rated motor current
Maximum Value 200% rated motor current
Default Value 50% rated motor current
3000RPMMaximum
8VDCMaximumCommand
-----------------------------------------------------------------------------
3000RPM
Volts
----------------------------=
MaximumDesiredMotorRPM
Max
i
mumVelocityCommand
------------------------------------------------------------------------------------
RPM
Volts
---------------=