User manual
Publication 1394-5.0 — May 2000
7-4 Commissioning Your 1394 Analog Servo System
7.
Setting Up at the System Level
This procedure assumes that you have wired your 1394 Analog Servo 
System and have completed the procedure Removing and 
Re-Applying Power earlier in this chapter.
When the LEDs on the system and axis modules are all flashing green 
and the Sys Ready message appears on the HIM, you are ready to 
begin these procedures.
To perform system-level setup:
1. At the HIM, press ENTER. A message similar to the following 
appears:
2. Press either the up or down arrow key until the following appears:
3. Press ENTER. The following message appears:
4. Press ENTER. A message similar to the following appears:
5. Press SEL. The cursor moves to the bottom line.
6.
If the system module LED: Then:
Flashes green and the following 
appears on the HIM:
Sys Ready
The control and bus power are 
active, but the modules are not 
enabled. Go to Setting Up at 
the System Level.
Flashes red and green, flashes 
red, remains solid red, does not 
illuminate
You may have a wiring 
problem. Go to the 
Troubleshooting chapter.
Choose Mode 
Display
Choose Mode 
Start Up
ALLEN-BRADLEY
COPYRIGHT 1994
Line Voltage
460 Volts AC
If you are using: Do this:
480 V AC Press ENTER. The system records your 
choice.
360 V AC 1. Press either the up or down arrow key 
until 360 Volts AC appears.
2. Press ENTER. The system records 
your choice.