User Guide
9 • Schlage • XE360 Locks user guide
Commissioning
Commissioning is the process of adding the lock into the access control system.
Once commissioned, the lock(s) can be controlled using Allegion Engage™.
1. Power the lock. The initiation sequence will begin. Wait for a steady blue
light and one (1) beep.
2. Press and release the mode switch to enter manual commissioning mode.
3. Open the Engage Mobile Application and follow the steps to connect the
lock.
4. The lock will blink one (1) long blue light when commissioning is complete.
The lock will be displayed in the app.
5. Once the sequence is complete, the lock will disconnect. The lock will now
operate in normal mode.
Lock modes
Normal mode
Once the lock is commissioned, it can be controlled using Allegion Engage.
Multi-family construction mode
When in multi-family construction mode, the lock may be unlocked by presenting any credential with the same 48X-type
and facility code.
1. While the lock is in FDR mode, press and hold the mode switch for three (3) seconds. The lock will blink one (2) green
light, and beep one (1) time, and enter construction mode.
2. Within twenty (20) seconds, present a 48X-type credential, with a valid facility code, to the lock. The lock will blink four
(4) green lights and beep one time.
3. The lock will now operate in multi-family construction mode.
Commercial construction mode
When in commercial construction mode, the lock may be unlocked by presenting a registered credential.
1. While the lock is in FDR mode, press and hold the mode switch for three (3) seconds. The lock will blink one (1) green
light, and beep one (1) time, and enter construction mode.
2. Within twenty (20) seconds, press and hold the mode switch and present a master credential to the lock. Then release
the mode switch. The lock will blink five (5) green lights and beep one time.
3. The lock will now operate in commercial construction mode.
Register a commerical construction credential
1. While in Commercial construction mode, present a master credential to the lock. The lock will blink one (1) green light
and beep one (1) time.
2. Present a new credential to the lock. This credential will become a registered commercial construction mode credential.
3. This credential may now be used to unlock the lock.