User Guide

12 • Schlage • XE360 Locks user guide
Troubleshooting
Troubleshooting
Problem Solution
Manual commissioning failed. When commissioning fails, the lock will revert to FDR mode. Press and
release the mode switch again to restart the process.
Confirm that bluetooth is enabled on the mobile device.
Confirm that the mobile device is not currently connected to another
device.
Confirm that the lock is displaying steady
blue LED. If not, restart the
process by pressing and releasing the mode switch.
DPS not responding Cycle power on the lock and try diagnostics again.
If cycle of power does not work, remove lock from door, disconnect power
and verify DPS cable is not pinched or has become disconnected. If that
is the case, reconnect and proceed to re-install then repeat diagnostics.
REX not responding Cycle power on the lock and try diagnostics again.
If cycle of power does not work, remove lock from door, disconnect power
and verify REX Switch cable is not pinched or has become disconnected.
If that is the case, reconnect and proceed to re-install then repeat
diagnostics.
Factory default reset
1. Remove lock cover.
2. Press and hold button for seven (7) seconds, until light turns
red.
3. Initiate FDR:
To perform FDR on the lock, press the button one (1) time. Lock will blink red two (2) times and beep two (2) times.
To perform FDR on the reader, press the button two (2) times. Lock will blink
red three (3) times and beep three (3)
times.
4. Wait for one (1) long
green light and one (1) long beep to confirm successful FDR.
FDR was not successful if lock blinks red two (2) times and beeps two (2) times.